Clamp on Flow Meters for Liquid Pipes

Clamp on flow meters refers to the non-contact flow meter, or strap-on flow meters, which clamps the ultrasonic sensor outside the pipeline for measurement.

Clamp on flow meters for liquid pipes

Clamp on flow meters installs the sensor clamp outside the pipe. No changes to the pipeline are required. The measurement is simple and flexible. Used for small to large pipe diameters. Clamp on flow meters can be installed permanently, or portable, hand-held, etc.

Sino-Inst offers a variety of  Clamp on flow meters for flow measurement. If you have any questions, please contact our sales engineers.

Best clamp-on flow meters for sale

Clamp On flow sensor for clamp-on flow meters

  • With powerful magnets, when measuring steel pipes and cast iron pipes, you only need to attach the sensor to the outer wall of the pipe.
  • High temperature sensor with high temperature resistant strong magnet, when measuring steel pipe and cast iron pipe, only need to attach the sensor to the outer wall of the pipeline.
  • Equipped with a ground wire terminal, it can be used in occasions with strong electromagnetic interference.
  • It can be fixed by steel belt, steel wire rope, tension belt and special clamp.
  • The upper cover of the sensor marked the emission direction of the ultrasonic signal.
  • After the junction box is filled with glue, the protection level can reach IP68.
  • Complete specifications, divided into three types of large, medium and small, measuring pipe diameter range DN15~DN6000mm, temperature range: -40~90℃. -40~160℃.
  • According to different uses, standard clamp-on sensors are divided into two categories: portable and fixed.
Types Picture Spec. Model Measurement Range Temperature Dimension
Clamp on  Small Size TS-2 DN15~DN100 -30~90℃ 45×25×32mm
Medium Size TM-1 DN50~DN700 -30~90℃ 64×39×44mm
Large Size TL-1 DN300~DN6000 -30~90℃ 97×54×53mm
High
Temperature
Clamp on
Small Size TS-2-HT DN15~DN100 -30~160℃ 45×25×32mm
Medium Size TM-1-HT DN50~DN700 -30~160℃ 64×39×44mm
Large Size TL-1-HT DN300~DN6000 -30~160℃ 97×54×53mm
Mounting
Bracket
Clamp on
Small Size HS DN15~DN100 -30~90℃ 318×59×85mm
Medium Size HM DN50~DN300 -30~90℃ 568×59×85mm
Extended EB-1 DN300~DN700 -30~90℃ 188×59×49mm
High
Temperature
Mounting
Bracket
Clamp on
Small Size HS-HT DN15~DN100 -30~160℃ 318×59×110mm
Medium Size HM-HT DN50~DN300 -30~160℃ 568×59×110mm
Extended EB-1-HT DN300~DN700 -30~160℃ 188×59×49mm

Extended Reading: Liquid Turbine Flow Meter

Portable Clamp On flow meters

Portable clamp-on flow meters refer to the host form of clamp-on flow meters.

Of course, the host of Clamp-on flow meters can be portable, hand-held, and permanently fixed.

A handheld ultrasonic flow meter realizes the non-contact measurement of liquid flow. Also often referred to as Portable Clamp-On Ultrasonic Flow Meter for Liquids.

Handheld Ultrasonic Flow Meter ( Model:2000H) has been successfully applied to measurement work in various industries. The measuring range is 20-6000mm (0.5-20 inches). A non-contact measurement method is adopted. Flexible operation and easy to carry. Conductive or non-conductive, corrosive or non-corrosive liquids can be measured. Various fluids: water, pure water, sewage, seawater, chemical fluids, river water, fuel Oil, etc. can be measured.

Handheld Ultrasonic Flow Meter Reference price: USD 470.00/pc

Read more about Digital Water Flow Meters

New Strap on flow meter X3

Strap-on flow meter X3 is a kind of ultrasonic external clamp-on flow meter. Strap on flow meter X3 is easy to install. Suitable for measuring pipe diameter Φ9.53~Φ90.

Strap on flow meter X3 can meet the needs of different pipe materials: stainless steel pipe, carbon steel pipe, copper pipe, plastic pipe, PVC, PVDF, PPH, PPE, etc.

Strap on flow meter X3 almost meets the measurement of different clean fluids: various acids, alcohols, chemical solvents, alcohol, drinking water, Coca-Cola water… etc.

Read more about: what is gpm;

Clamp On flow meters for water

Advantages of Clamp-on flow meters to measure water:

  1. This is the most obvious difference between the clamp-on ultrasonic flowmeter and the electromagnetic flowmeter. The clamp-on ultrasonic flowmeter is not affected by the conductivity of the fluid. It can accurately measure pure water or other fluids with low conductivity that cannot be measured by electromagnetic flowmeters.
  2. The accuracy of the clamp-on ultrasonic flowmeter fully meets the measurement requirements. The accuracy is usually ±1%, and ±0.5% after correction.
  3. The external clamp ultrasonic flowmeter has a measuring probe outside the pipe wall. It is tightly connected to the pipe wall through a coupling agent. It is not in direct contact with the measured medium. There is no baffle, and its operating life can be well guaranteed.
  4. Strong anti-interference ability. The power supply has a wide range to meet the needs of the site.
  5. The external clamp type ultrasonic flowmeter is also very convenient to install. Just install the external clamp sensor on the outer pipe to avoid cutting off the pipe and polluting the demineralized water.

You may like: Digital Flow Meters Guide| Liquid and Gas

Clamp-on flow meter for gas

The gas ultrasonic flowmeter can not only measure high-pressure gas, but also measure atmospheric gas, including gas in steel pipe, which was a worldwide technical problem before.

For example air, argon, carbon monoxide, ethane, ethylene, helium, hydrogen, natural gas, nitrogen, nitrous oxide, oxygen, process gas, propane, saturated steam, acid gas, etc.

You may like:

Frequently
Asked
Questions

Clamp-on flow meters can be installed on new or existing pipes and sit on the outside of the pipe. This saves time and money since no cutting into the pipe is required. 

Clamp on Ultrasonic Flow Meter adopts the measurement principle of time difference method. It uses the ultrasonic wave emitted by the sensor to propagate in the flowing fluid. The sound wave propagation speed in the downstream direction will increase, and the backward direction will decrease. In the same propagation distance, there will be different transmission times. According to the difference between the transmission time and the measured The relationship between fluid velocity measures the fluid velocity.
The flow rate of the fluid is different in different positions in the tube. The flow rate in the center of the tube is faster than the flow rate near the wall of the tube. The flow velocity distribution of the fluid in the pipeline can be represented by the flow velocity cross-sectional distribution diagram.
By setting the flowmeter and considering the cross-sectional distribution of the flow velocity, the average flow velocity can be calculated. Then the volume flow of the fluid can be obtained according to the cross-sectional area of the pipe.

Notes:
V measure fluid velocity
M ultrasonic reflection times
D pipe diameter
θ The angle between the ultrasonic signal and the fluid
T up The time when the downstream sensor transmits the signal to the upstream
T down Time from upstream sensor to downstream
ΔT = T up – T down

Read more about: Ultrasonic flow meters types & technical guide

Ultrasonic flowmeters use sound waves to determine the velocity of a fluid flowing in a pipe.
At no flow conditions, the frequencies of an ultrasonic wave transmitted into a pipe, and its reflections from the fluid are the same.
Under flowing conditions, the frequency of the reflected wave is different, due to the Doppler effect.
When the fluid moves faster, the frequency shift increases linearly.
The transmitter processes signals from the transmitted wave, and its reflections to determine the flow rate.

Extended reading: Ultrasonic Insertion Flow Meter for Lined/Large Pipes

Sino-Inst, Manufacturer for Ultrasonic Flow Meters. It can measure a single sound-conducting liquid medium of DN 15—6000mm. It can measure even liquids such as water, seawater, oil, and slurry.

Sino-Inst’s Ultrasonic Flow Meter, made in China, Having good Quality, With better price. Our flow measurement instruments are widely used in China, India, Pakistan, the US, and other countries.

This entry was posted in Flow Measurement Solutions, Blog by KimGuo11. Bookmark the permalink.

About KimGuo11

Wu Peng, born in 1980, is a highly respected and accomplished male engineer with extensive experience in the field of automation. With over 20 years of industry experience, Wu has made significant contributions to both academia and engineering projects. Throughout his career, Wu Peng has participated in numerous national and international engineering projects. Some of his most notable projects include the development of an intelligent control system for oil refineries, the design of a cutting-edge distributed control system for petrochemical plants, and the optimization of control algorithms for natural gas pipelines.