Coriolis Density Meter is also called Coriolis Concentration Meter. It adopts the principle of operating under the special law of the Coriolis force of the moving liquid. The Coriolis force is related to the density of the liquid, so the density value of the liquid is measured. The concentration is calculated from the density and temperature. The Coriolis principle has high stability, high precision, good long-term stability, and no drift caused by the sensor. Coriolis Density Meter is used in many industries like oil refining, sugar, paper, and chemical. It measures weak acid-base solutions in the wine, salt, and printing industries.

coriolis density meter

Features of Coriolis Density Meter

  1. The 4-wire transmitter with an integrated structure has no moving parts and is easy to maintain; the 4-wire transmitter has 4-20mA output;
  2. Real-time display of five-digit density value, four-digit decimal (one digit for concentration), real-time indication of current and temperature;
  3. You can directly enter the instrument menu to set parameters;
  4. It is easy to install and use, and the reading can be displayed when the flange surface touches the liquid;
  5. It is used for fluid or static liquid, suitable for pipeline installation or installation on container wall, etc.;
  6. Density and concentration have the functions of pure water calibration, fine-tuning of measured value and temperature compensation;
  7. Continuous online measurement without process interruption, can be directly used for production process control;
  8. All parts in contact with liquid are made of 316 stainless steel or polytetrafluoroethylene, which is safe, hygienic and has good corrosion resistance;
  9. Measuring high viscosity and non-Newtonian flow can also measure uniform multiphase flow;

Technical Parameters

Accuracy±0.001g/cc±1.0kg/m3
The scope of work0~3g/cc0~3000kg/m30~187.4 lb/ft3
Repeatability±0.001g/c±0.1kg/m3±0.006lb/ft3
Process temperature effect (corrected)±0.001%g/cc)±0.1kg/m3(per °C)
Process pressure effect (corrected)can be ignored
(1) The above accuracy is applicable to the calibration range of 0.6-1.25g/cc (600-1250kg/m3)
(2) When a long rod is used, the maximum viscosity of the liquid can reach 500CP, but if it is used, the maximum viscosity of the liquid can reach 20000CP.
(3) Temperature effect refers to the maximum measurement deviation caused by the process fluid temperature deviating from the factory calibration temperature.
(4) Pressure effect is defined as: the change in sensor flow and density due to process pressure deviation from calibration pressure.
Process temperature–10℃~+60℃
Ambient temperature–10℃~+85℃
Temperature CoefficientO.1kg/m3/℃ (after correction)
Built-in temperature sensorPT100
Wetted partsStainless steel 316L, titanium, etc. can be customized
ShellIP65, aluminum alloy
Tine polishingStandard, PFA coated or electropolished
Working pressure3000psi (207bar)
1450psi (100bar)
Test pressureTested at 1.5 times the maximum working pressure
Actual maximum working pressure is limited by process connection rating
Process connection typeflange
Clamp
thread
Explosion-proof certificationEx d Ⅱ B T6 Gb
Power requirements24VDC,50mA
OutputFour-wire system, 4-20mA transmission 4-20mA, optional RS485-Modbus RTU communication
Viscosity range0-20000CP

Fluid and Material Compatibility

TypeNameMolecular formulaConcentration (%)316LHastelloyTitanium alloyzirconiumPTFE
AcidHydrochloric acid (without hydrofluoric acid)HCI0-40××
sulfuric acidH2SO40-50
H2SO450-75××
H2SO475-98
nitric acidHNO30-100
phosphoric acidH3PO40-98××××
Alkalisodium hydroxideNaOH0-50
Potassium hydroxideKOH0-50
Calcium hydroxideCa(OH)20-50
SaltSodium chlorideNaCI0-50×
ammonium chlorideNH4CI0-50×
ammonium sulfate(NH4)2SO40-50×
Otherscarbamide(NH2)2CO0-100
sodium hypochloriteNaOCI0-16××
hydrogen peroxideH2O20-90
☆Recommended
○ Use under specific concentration and temperature limits
× Do not use

Featured Types of Coriolis Density Meters-Concentration Meters

Coriolis density meter industrial applications

The Coriolis density meter is based on the principle of special laws under the action of the Coriolis force of the moving liquid. The Coriolis force is related to the density of the liquid, so as to measure the density of the liquid; then according to the relationship between density and concentration The relational table obtains concentration values at a temperature of 20°C.

Coriolis density meter can be widely used in the detection of oil refining and blending in the petrochemical industry. The food industry is used in sugar industry, vegetable oil and beverage processing, etc. Production site, paper industry, measurement of weak acid-base solution in chemical industry, wine industry, salt, printing and dyeing and other industries. Due to the large flow pipe, it is especially suitable for occasions that are not dry or viscous. It is suitable for pipe installation.

Medium limitationContain gasMaximum Liquid Viscosity
Regular liquidAcid and alkali solution
316LTitaniumContain gas

Generally do not use
20000CP

Typical application conditions:

Petroleum and petrochemical industry— Quality Control — Continuous Online
Wine industry— Quality control — Continuous online inspection
Organic and Inorganic Chemical Materials— Acid/base concentration control
Pharmaceutical Industry— Traditional Chinese medicine concentration, alcohol recovery
Battery industry— Concentration of lithium hydroxide, electrolyte, sulfuric acid solution
Mineral processing— Clays, carbonates, silicates

More Density meter and measurement analysis solution

Coriolis mass flowmeter is a kind of instrument that is commonly used at present and has relatively high stability and reliability of measurement accuracy. Coriolis mass flow meters are not only capable of measuring mass flow meters from Micro Motion, but also of media density.

When the Coriolis Density Meter measures density, its measuring tube vibrates continuously at a certain resonant frequency. Because the resonance frequency is a function of the fluid density. When fluids of different densities fill the vibrating tube, its vibration frequency will also change. Therefore, measuring the frequency change of the vibrating tube completes the density measurement. The linear relationship between the density and the vibration frequency of the vibrating tube.

This method is accurate and reliable in measurement, and is suitable for a wide measurement range of various fluid densities. The pressure loss of Coriolis Density Meter is very small, and it has inherent advantages in measuring the density of viscous fluids such as mud.

There are more and more requirements for density measurement in the current production process, and the accuracy of density measurement directly affects the quality of production process.

We Sino-Inst manufacture and supply many kinds of Coriolis Density Meters-Concentration Meters. Our Coriolis Density Meters are exported to various countries like USA, UK, Germany, Nigeria, Saudi Arabia, Singapore, etc. If you need to measure density, please feel free to contact our sales engineers.

Request a Quote

Coriolis Density Meter-Concentration Meter | Sino-Inst

Coriolis Density Meter is also called Coriolis Concentration Meter. It adopts the principle of operating under the special law of the Coriolis force of the moving liquid. The Coriolis force is related to the density of the liquid, so the density value of the liquid is measured. The concentration is calculated from the density and temperature. The Coriolis principle has high stability, high precision, good long-term stability, and no drift caused by the sensor. Coriolis Density Meter is used in many industries like oil refining, sugar, paper, and chemical. It measures weak acid-base solutions in the wine, salt, and printing industries.

Product SKU: Coriolis Density Meter-Concentration Meter

Product Brand: Sino-Inst

Product Currency: USD

Product Price: 6000

Price Valid Until: 2029-09-09

Product In-Stock: InStock

Editor's Rating:
5