Target Flow Meter

The target flow meter is also known as the drag force flow meter. Insert a target (drag element) into the flow field. Measure the drag force on the inserted target and convert it to the flow velocity.

Target Flow Meter

The target flow meter is also called a drag force flowmeter. The target flow meter inserts a target (drag element) into the flow field. The target usually is a flat disc or a sphere with an extension rod. There will be a differential pressure. And then target flow meters measure the drag force on the inserted target and convert it to the flow rate. Sino-Inst manufactures target flow meters for liquid, gas, and steam measurement.

Sino-Inst, Manufacturer for differential pressure flow meters. Including the Orifice plate, Venturi, Annubar, etc. Suitable for liquid, gas, and steam flow measurement. Please contact our sales engineers for technical support!

Target Flow Meter Definition

Sino-Inst offers a Capacitive target flowmeter. A capacitive target flowmeter is a new type of capacitive force inductive flowmeter. Developed on the basis of traditional target flowmeter. And developed with new sensors and microelectronic technology. It has both orifice plate and vortex flowmeters.

The characteristics of no moving parts. High sensitivity, accuracy comparable to volumetric flow meters, and a wide range. The use of a chip-level capacitive force sensor and an efficient anti-overload structure design are the key cores for the new product to achieve high precision and high stability.

In addition, it has unique anti-interference and anti-impurity performance. Our capacitive target flow meters can replace the conventional flow measurement. It has good adaptability to difficult flow measurement conditions. Such as high viscosity, dirty media, easy to set and block, high temperature, low temperature, and strong corrosion.

It is widely used in petroleum, chemical industry, metallurgy, power. Pharmaceutical, environmental protection, food and other fields.

The target flow meters are applicable to the following ranges:

  • Diameter ,Φ15~Φ2000mm or bigger.
  • High and low temperature, -196°C~+450°C.
  • High pressure : 0~42Mpa.
  • Suitable for various media: gas, liquid (including high viscosity liquid, slurry), steam;
  • It is suitable for low-velocity media, and its minimum measurable flow rate is 0.08m / s.

Target Flow Meter Construction

The capacitive target flowmeter is mainly composed of a measuring tube (housing), a new capacitor.

It consists of a force sensor, chokes, integrated display, and output.

Target Flow Meter Construction

Features of Target Flow Meters

  • The whole instrument has a solid structure without moving parts, easy to disassemble.
  • Can choose a variety of anti-corrosion. And high and low temperature resistant materials (such as Hastelloy, titanium, etc.);
  • The whole machine can be made fully sealed without dead corners (welded form). Without any leakage points, and can withstand 42MPa high pressure;
  • Small pressure loss, only about 1/2 △ P of standard orifice plate;
  • Strong anti-interference and anti-impurity capabilities;
  • The instrument has a self-checking program. And the failure phenomenon is clear at a glance;
  • The sensor is not in contact with the measured medium, there is no component wear, and it is safe and reliable to use;
  • Dry calibration method can be used in situ, that is, weight hanging method. One-button operation can complete the calibration;
  • There are multiple installation methods to choose from. Such as online plug-in, low installation costs;
  • With integrated temperature and pressure compensation, direct output quality or standard square;
  • Optional small signal removal, non-linear correction, and filtering time can be selected;
  • It can accurately measure the gas and liquid flow under various normal temperature. High temperature 500 degrees, and low temperature -200 degrees;
  • Accurate measurement, accuracy can reach 0.2%;
  • Good repeatability, generally 0.05% to 0.08%, fast measurement;
  • Can change the range of resistance (target) according to actual needs;
  • Low-power battery on-site display, can directly read the displayed value online. And the display can read the instantaneous and cumulative flow and percentage bar graph at the same time;
  • Simple and convenient installation and extremely easy maintenance;
  • Multiple output formats, which can transmit various parameters remotely;
  • Strong vibration resistance, pulsating flow can be measured within a certain range.

Target flow meters types

Technical Data of Target Flow Meter

Item                                         Target flowmeter Performance, Parameters
MediumLiquid, Gas, and Steam
CaliberPipe type 15~300mm   
Clamp type 15~600mm    
Plug type100~2000mm
Pressure0.6~10MPa
0.6~42MPa 
0.6~42MPa
Accuracy± 0.2    ~   ± 1.5%FS
Medium Temperature-196° C~+450° C
( Confirming the temperature range before purchase)
Media temperature-20   ~ +70 (normal temperature type)
-196 ~   +700 (high/low temperature type)
Precision± 0.2%          ± 0.5%          ± 1.0%            ± 1.5%             ± 2.5%
Range1: 3           1: 5        1: 10        1: 10 1: 10(Steam)
CompensationTemperature compensation; Pressure  compensation
Repeatability0.1%~0.08%
Power Supply3.6V lithium battery, 24V DC
OutputLCD display, and 4~20mA, 0~10V, impulse or RS485 (Optional)
Material of measure tubeCarbon Steel; 304; 316L; Being able to provide other according to user requests
Explosion- Prevent SymbolExiallCT4, ExiallBT4
Protection RankIP65; IP67
Features* Installation is simple and convenient, easy to maintain
* A variety of output forms, spread far and wide variety of parameters
* Anti-vibration is strong, within a certain range can be measured pulsatile flow
* Anti-jamming, anti-contamination ability to exceptionally strong

Advantages of Target flow meters:

  • They are useful for difficult measurements. Such as slurries, polymer bearing and sediment-bearing materials corrosive mixtures, etc.
  • They provide good accuracy when calibrated for specific streams.
  • They are good for relatively high temperatures and pressures.
  • Low initial set up cost
  • Can be used with a wide variety of fluids, even viscous fluids and slurries.
  • Can be used in abrasive, contaminated, or corrosive fluid flow
  • Can be made to measure flow velocity that is sporadic or multi-directional with sphere drag element designs
  • Can be used for any type of liquid, gas, or steam cryogenics.
  • There is no moving parts such as bearings, to wear out causing failures.
  • High reliability where life tests have been made to 20,000,000 cycles.
  • Can be used for any line size from 0.5 inches and up with any type of mounting.
  • Range/fluid changes accomplished by simply changing targets.
  • Turndowns aprox.15:1
  • Several materials are available. Among them 303/304 SS, 316 SS, hastelloy and inconel.

Disadvantages of target flow meters:

  • Calibration must be verified in the field.
  • Pressure drop is inevitable due to the rod and the drag element
  • In-line mounting required in these flowmeters.
  • They have a limited calibration data.
  • In case of target flowmeters no-flow conditions must exist for zeroing

Target Flow Meters Applications

Gas: gas, air, hydrogen, natural gas, nitrogen, liquefied petroleum gas, hydrogen peroxide, flue gas, methane, butane, chlorine, etc.

Liquid: heavy oil, paraffin, asphalt, sulfuric acid, cooking oil, residue oil, acetone, diesel, mine water, detergent, soy sauce, gasoline, silicone oil,

Syrup, solvent, perfume, seawater, aviation kerosene, soap ketone, glucose, canola acid, saltwater, paste, ink, coolant,

Glycol, mineral oil, liquid sugar, hydrochloric acid, automotive coatings, resin, butter, vegetable oil, liquid oxygen, shampoo, toothpaste, gel,

Fuel, milk, bleach, conditioner, soda, additives, cleaning agents, alkaline, ammonia, marine oil, chemical reagents, kerosene,

Glycerin, dye, water, nitric acid, high boiling point organic solution, lard, alcohol, oil, ethylene, polypropylene, methyl benzyl, etc.

Steam: Superheated steam, saturated steam.

Extended reading: Vortex Steam Flow Meter

Application Cautions for Target Flowmeters

  • Be careful when operating target flowmeters low in their flow range. Because accuracy can be compromised at these flow rates.
  • Avoid abrasive fluids. Because the target can be damaged and measure inaccurately.
  • Fluids that coat the target can cause it to become heavy. Such that the force measurement can become inaccurate and unresponsive to flow changes.
  • These flowmeters should not be applied to slurries and high viscosity liquids.
  • Calibration is an important part of ensuring accurate operation of target flowmeters.
    • Pressure effects, physical effects, and flowmeter orientation can affect the zero adjustment of target flowmeters.
    • After calibrating the target flowmeter (typically with weights), be sure to zero target flowmeters after installation with a full pipe under no flow conditions. To ensure compensation for these effects in the final installation.
    • This procedure also compensates for the calibration shift that can occur when the orientation of the flowmeter during calibration is different than its installed orientation.
    • In general, in-situ zero adjustment should be performed after re-installing target flowmeters.
  • Operating a target flowmeter above its maximum flow rate can cause the calibration to shift and potentially damage the suspension system of the flowmeter.
  • Note also that operating target flowmeters continuously for extended periods of time can cause a mechanical shift to occur that can affect the zero. Because the target may not return to exactly the same position after being exposed to forces over time.
  • Rapidly changing flow, such as slug flow conditions, two-phase flow, and start-up conditions (gas to liquid transitions). Can similarly affect the mechanics of the target flowmeter and hence its zero. Therefore, it is advisable to periodically verify the zero adjustment of target flowmeters.

Target Flow Meter Working

When the medium flows in the measuring tube, the pressure difference caused by its own kinetic energy passing through the blocking member (target). And has a force on the blocking member. The magnitude of the force is proportional to the square of the velocity of the medium.

The mathematical way is as follows:
F = CdAρ • V2 / 2

In the formula: F —— the force of the choke (kg)
Cd-object resistance coefficient
A ——Axial projection area of ​​the choke on the measuring tube (mm2)
ρ ——Density of medium under working conditions (kg / m3)
v-average flow velocity of the medium in the measuring tube (m / s)
The force F received by the choke member (target) is transmitted to the capacitive force sensor via a rigidly connected transmission member (stem).

And the capacitive force sensor generates a voltage signal output:
V = KF
In the formula:
V——Voltage output by the capacitive force sensor (mV), K——Proportional constant, F——The acting force of the choke (target)
So, after the voltage signal is pre-amplified, AD converted. And processed by the computer. The corresponding instantaneous flow and cumulative total can be obtained.

How Target Flowmeters Work

Target flowmeters measure flow by measuring the amount of force exerted by the flowing fluid on a target suspended in the flow stream.

The force exerted on the target by the flow is proportional to the pressure drop across the target.

Like differential pressure flowmeters. Bernoulli’s equation states that the pressure drop across the target (and hence the force exerted on the target) is proportional to the square of the flow rate.

Using this relationship, 10 percent of full scale flow produces only 1 percent of the full scale force.

At 10 percent of full scale flow, the target flowmeter accuracy is dependent upon the transmitter being accurate over a 100:1 range of force.

Transmitter accuracy is typically degraded measuring low forces in its range, so flowmeter accuracy can be similarly degraded.

So, this non-linear relationship can have a detrimental effect on the accuracy and turndown of target flowmeters.

Remember that of interest is the accuracy of the flow measurement system — not the accuracy of the transmitter.

How to Use Target Flowmeters

  • Target flowmeters inferentially measure the flow of liquids and gases. Such as water, air, industrial gases, and chemicals.
  • Be careful using target flowmeters on fluids that can coat the target. Because the flowmeter accuracy can be degraded.
  • This flowmeter can be applied to sanitary, cryogenic liquids, relatively clean, and corrosive liquids.
  • Thematerials of construction of all wetted parts, including the flowmeter body and seals, should be considered.
  • Inline target flowmeters are available up to approximately 6 inches in size.
  • Insertion target flowmeters are available for larger line sizes.
  • Applications requiring sanitary piping systems are often found in the pharmaceutical and chemical industries. Such as in the manufacture of drugs and vitamins.
  • Sanitary applications are especially prevalent in the food and beverages industry where cleanliness is important.
  • Applications for target flowmeters are found in the mining, mineral processing, pulp and paper, power, petroleum, chemical, and petrochemical industries.
  • Common applications include the measurement of process and cooling water flows.

More Technical Support

How does a turbine flow meter work?

How does a vortex flowmeter work?

What does a Coriolis meter measure?

https://www.drurylandetheatre.com/coriolis-mass-flow-meter-si3131/

You may like:

Frequently
Asked
Questions

As the most accurate and also the most expensive technology, Coriolis mass flow meters are the main instrument type used in scientific applications. They can measure corrosive and clean gases and liquids.

Coriolis mass flow meters are designed and produced according to the world’s latest Coriolis technology. It has a better appearance, stability, and accuracy. It can measure the mass flow of fluids flowing through the pipeline and is widely used in alternative energy, oil and gas, chemical, food, and other fields. Beverages, industrial energy, marine, metal and mining, power, pulp and paper, water and wastewater industries, etc.

Flow meters are the eyes of industrial production. Flow measurement is one of the components of measurement science and technology. It is closely related to the national economy, national defense construction, and scientific research. Doing this job well plays an important role in ensuring product quality, improving production efficiency, and promoting scientific and technological development. Especially in today’s energy crisis and the era of increasing automation of industrial production, the status and role of flow meters in the national economy have become more obvious.

Turbine flow meters are velocity flow meters, also called impeller flow meters. Can be used to measure the instantaneous flow and cumulative flow of liquids and gases.

Turbine flowmeters are widely used in flow measurement: petroleum, organic liquids, inorganic liquids, liquefied gas, natural gas, coal gas and cryogenic fluids. Turbine flowmeter signals can be divided into pulse signals or current signals (4-20mA). It is suitable for use with secondary display, PLC, DCS and other computer control systems.

Turbine Flow Meter reference price: USD 200-1700/pc.

Vortex shedding flow meter is also called Vortex flow meter. Vortex shedding flow meter is suitable for measuring steam flow rate as well as liquids and gases.

Vortex shedding flow meter, easy installation, low cost, analog, and 4-20mA output. Pressure & temperature compensation can improve the sensor for more accurate measurement. Vortex shedding flow meter is suitable for measuring steam and various liquids and gases. When the fluid flows through the assembly line of the vortex flowmeter, a vortex is formed. The frequency of vortex shedding is directly proportional to the fluid velocity.

Vortex shedding flow meter reference price: USD 200-1500/pc.

Sino-Inst offers over 10 target flow meters for flow measurement. About 50% of these are liquid flow meters, 40% is the gas flow sensor and 20% are steam flow meter.

A wide variety of flow meters options are available to you, such as free samples, paid samples.

Sino-Inst is a globally recognized supplier and manufacturer of Target flow measurement instrumentation, located in China.

Request a Quote

Industrial Inline Air Flow Meters

What is air flow meter?

An Air Flow Meter is the flow meter that measures industrial air velocity. Most of the time, people talk about air flow meters means compressed air flow meters. We are discussing here all air flow meters, including compressed air flow meters.

Vortex Flow Meters

Compressed Air Flow Meter, is the digital flow meter work for the air compressor. Air consumption is important info for industrial inline gas flow pipes. According to the measurement conditions, a compressed air flow meter could be of different types. Thermal mass flow meters, Ultrasonic flow meters, vortex flow meters, Turbine flow meters. And the differential pressure flow meters (Orifice plate ) are also suitable for compressed air. With the Pressure and Temperature compensation. Sino-Inst’s compressed air flow meters are more affordable and complete.

There are many types of instruments that can be used to measure air. However, there are not many types of airflow actually used in the field according to their principles. The most important ones are rotameter, throttling differential pressure flowmeter, vortex flowmeter, gas turbine flowmeter, and averaging velocity tube flowmeter.

Extended Reading: Digital air flow meters

Featured Inline Air Flow Meters

Air flow meters types

The Carmen vortex refers to the placement of a cylindrical or triangular object in the fluid. Two rows of vortices with opposite rotation directions will be generated downstream of this object.

More about Types Of Air Flow Measurement Instruments.

An ultrasonic transmitting probe and a receiving probe are oppositely installed on both sides of the downstream pipeline of the Carmen vortex generator. Due to the influence of the Carmen vortex on the air density, the time from the transmitting probe to the receiving probe of the ultrasonic wave becomes later than that of the non-vortex and a phase difference occurs. By processing this phase signal, a vortex pulse signal can be obtained.

The working principle of the hot film type air flow meter is similar to that of the hot wire type air flow meter, and they all work with Wheatstone bridge. The difference is that the hot film type does not use platinum wire as a hot wire. But uses a thick film process to make the hot wire resistance, compensation resistance, and bridge resistance on the same ceramic substrate.

In the process of generating the Carmen vortex, the air pressure on both sides of the vortex generator will change. The pressure acts on the metal foil through the pilot hole, causing it to vibrate. When light from a light-emitting diode strikes a vibrating metal foil. The reflected light on the metal foil received by the phototransistor is vortex-modulated light. And its output is demodulated to obtain a frequency signal representing the air flow.

When no air flows, the bridge is in equilibrium. The control circuit outputs a certain heating current to the hot wire resistance RH. When there is air flowing, the heat of RH is absorbed by the air and becomes cold. Its resistance value changes. The bridge loses Balance. If the temperature difference between the hot wire resistance and the intake air is kept constant and constant, the current IH flowing through the hot wire resistance must be increased. Therefore, the hot-wire current IH is a function of the mass air flow.

The vane type air flow meter has a simple structure and high reliability. Yet, it has a large volume, large intake resistance and slow response.

Read more about: Beginner’s Guide: Variable area flow meter

Inline air flow meter cfm-scfm-lpm

Inline air flow meter cfm

CFM is a common imperial flow unit, cubic feet per minute.
For a certain volume of air flow passing in a unit time, m3/h air volume unit is generally used in China. Other countries also use the British air volume unit cfm (cubic foot per minute). That is ft3/min cubic feet/minute,
1CFM=28.316846592 L/MIN=0.028316847 m3/min

CFM traffic is divided into SCFM and ACFM.

Inline air flow meter scfm

SCFM English standard cubic foot per minute means standard cubic foot per minute, British flow unit. Both ACFM & SCFM are units of measurement for English flow
ACFM=actual flow rate ft^3/min

SCFM=standard flow rate ft^3/min

Convert
1 cubic meter = 35.314724827664 cubic feet
1Nm^3/min=35.315 SCFM
1 liter/minute=0.03531SCFM
1 liter=0.03531SCFM

Inline air flow meter lpm

LPM is liter/minute.

Read more about Inline air flow meter units conversion

More Air Flow Meters solutions

Digital air flow meters

What Is Digital Air Flow Meters? The digital air flow meter is also a digital gas flow meter. The digital…

Inline Air Flow Meters

Featured Inline Air Flow Meters Inline air flow meter units conversion Inline air flow meter cfm CFM is a common…

Gas Mass Flow Controller

The gas mass flow controller is based on the principle of thermal mass flow measurement. With control valve. The Micro…

2 inch Water Flow Meter

2 inch water flow meter is also written as 2″ flow meter. If you are planning to buy a 2…

Industrial Oxygen Flow Meters

Oxygen Flow Meters are digital flow meters that can measure industrial oxygen. It is very important to choose a suitable…

Industrial CO2 flow meters

CO2 flow meters are instruments that can measure the flow of gaseous or liquid carbon dioxide. CO2 is a common…

LPG flow meters

LPG flow meter is used for flow measurement of liquefied petroleum gas. The flow measurement of LPG is very important…

Air flow meter price

The price of AIR flow meters are decided by flollowing factors:

  • Pipe diameter;
  • Flow range;
  • Measured medium;
  • Whether it is corrosive;
  • Whether explosion protection is required;
  • Whether it needs local display;
  • Connection method;
  • Measure pressure;
  • Measure temperature;
  • Signal output;
  • Accuracy requirements;
  • Material requirements;

Extended reading: Gas Rotameter Tips

Important factors when selecting flow metering devices are

  • accuracy
  • cost
  • legal constraints
  • flow rate range
  • head loss
  • operating requirements
  • maintenance
  • lifetime

These factors are more or less related to each other. Example – the cost of flow meters increases with accuracy and lifetime quality.

FAQ

What is an air flow meter called?

An airflow meter is a device that converts the inhaled airflow into electrical signals. Airflow meter is also often called gas flow meter, air mass flow meter, compressed air flow meter, etc.
Know more about Air flow meter From Wikipedia.

Sino-Instrument offers over 50 flow meter for flow measurement.

About 50% of these are differential pressure flow meters, 40% are the liquid flow sensor, and 20% are Ultrasonic Level Transmitter and mass flow meter.

A wide variety of flow meters options are available to you, such as free samples, paid samples.

Sino-Instrument is a globally recognized supplier and manufacturer of flow measurement instrumentation, located in China.

Request a Quote

Please enable JavaScript in your browser to submit the form

Turbine type Flow Meter

Turbine type flow meter is a Volume flowmeter. Turbine flow meters use the mechanical energy of the liquid or gas to rotate a rotor in the flow stream. The rotational speed of the rotor is proportional to the velocity of the fluid. In multiple industries, Turbine meters are used to measure the velocity of a variety of liquids, gases and vapors.

Turbine flow meter is the most popular equipment to measure flow electronically. Offer a wide flow and application rangeability. Turbine Flow Meters are easy to maintain, durable and versatile.

Turbine Flow Meters

What is a turbine flow meter?

A turbine flowmeter is a flowmeter that uses a turbine for measurement. It first converts the flow rate to the speed of the turbine. And then converts the speed into an electrical signal that is proportional to the flow. Turbine flow meter is used to detect the instantaneous flow and the total accumulated flow. And its output signal is frequency, which is easy to digitize.

Turbine flow meter advantages and disadvantages

Turbine Meter Advantages

  • The cost is moderate.
  • Very good at clean, low viscosity fluids of moderate velocity and a steady rate.
  • Turndown is very good as it can read very low compared to the greatest flow.
  • They are reliable if put in a clean fluid especially if it has some lubricity.
  • AGA and API approved for custody transfers.
  • They do cause some pressure drop where that may be a factor such as gravity flows.
  • High accuracy. Among all flowmeters, it is the most accurate flowmeter.
  • No zero drift, good anti-interference ability.
  • High accuracy. Among all flowmeters, it is the most accurate flowmeter.
  • No zero drift, good anti-interference ability.

Turbine Meter Disadvantages

  • Not reliable for steam.
  • Bearings wear out.
  • Requires constant backpressure to prevent cavitation.
  • Accuracy adversely affected by bubbles in liquids.
  • Turbine meters can be used with clean liquids and gases only (may need to install a strainer upstream to prevent damage from particulates).
  • Not applicable for measuring corrosive fluids.
  • May not function properly with high viscosity fluids where the flow profile is laminar.
  • Cannot maintain calibration characteristics for a long time.

Turbine flow meter principle

Turbine meters are simple to operate and maintain. Turbine type flow meter is a reliable, cost-effective method for accurate flow measurement. Turbine flow meters are designed to maximize throughout and minimize pressure drop. Turbine meters can maintain high flow rates over an extended flow range and offer pulse output linear to the flow rate. The turbine meters also minimize fluid measurement uncertainty. By delivering high-frequency pulse resolution to account for minute increments of the flow rate.

A turbine flow meter is constructed with rotor and blades. Turbine meters use the mechanical energy of the fluid to rotate the rotor in the flow stream. The turbine, installed in the fluid pipeline, is supported by bearings at both ends. When the fluid passes through the turbine, the fluid impacts the turbine blades and drives the turbine blades to rotate. The sensor of the turbine flowmeter measures the flow rate through the angular velocity of the turbine blades. The method used by the turbine flowmeter is that the angular velocity of the blade is proportional to the fluid velocity.

Turbine flow meter’s angular velocity is detected by a sensing coil mounted on the casing. Turbine blades cut magnetic field lines generated by permanent magnetic steel in the casing. Changes in the magnetic flux of the sensing coil. The sensing coil sends the detected periodic change signal of the magnetic flux to the amplifier of the measuring instrument. The amplifier amplifies and shapes the signal.At the same time, the pulse signal is sent to the frequency current conversion circuit. Convert the pulse signal into an analog current amount, which then indicates the instant Flow value.

Liquid Turbine Flow Meters

Extended reading: Turbine Flow Meter Specification

A flow transmitter processes the pulse signal to determine the flow of the fluid. Flow transmitter and sensing systems are available to sense flow in both the forward and reverse flow directions. 

Turbine flow meter Equation

In a certain flow range, the pulse frequency f is proportional to the instantaneous flow rate Q of the fluid flowing through the sensor.

The flow equation is:

Q = 3600 × f / k

In the formula:

f——pulse frequency [Hz];

k——meter coefficient [1 / m] of the sensor, given by the checklist. If [1 / L] is the unit

Q = 3.6 × f / kQ——the instantaneous flow of the fluid (in the working state) [m3 / h];

3600-conversion factor.

The instrument coefficient of each sensor is filled in the verification certificate by the manufacturer. The value of k is set in the matching display instrument, and the instantaneous flow and cumulative total can be displayed.

Extended reading: Quantitative control with turbine flowmeter

What is K factor in turbine flow meter?

The turbine meter measures volumetric flow, however the pulses produced vary depending on the meter. The variation is accounted for by a K-factor. The K-factor is the number of pulses per unit volume.

Simply stated a K-factor is a dividing factor. The term is usually encountered. When dealing with pulse signals although analog K-factors are sometimes used.

How do you calculate K factor for a turbine flow meter?

The frequency of the output pulse is proportional to the flow through the flowmeter, and its proportionality factor K is:

K = f / qv

Where:

f–the output pulse frequency of the turbine flowmeter;

qv–flow through the flowmeter.

This proportionality factor K is also called the meter factor of the turbine flowmeter.

Gas turbine flow meter

Gas Turbine Flow Meters applications

Gas Turbine Flow Meter, is the flange type turbine flow meter. Turbine flow meter is the most popular equipment to measure flow electronically. They offer a wide flow and application rangeability. 

Sino-Instrument’s GAS Turbine Flow Meter, is perfect choice for natural gas flow rate measurement. Turbine flow meters are suitable for gas and liquid measurement. They offer a wide flow and application rangeability. Turbine Flow Meters are easy to installation, maintain, durable and versatile.

Turbine water flow meter

Liquid Turbine Flow, is the turbine flow meter that suitable for liquid flow rate measurement. Like water flow, Diesel flow. Turbine flow meter is the most popular equipment to measure flow electronically. They offer a wide flow and application rangeability. Turbine Flow Meters are easy to maintain, durable and versatile.

Full bore turbine flow meters are suitable for hot and cold water applications. The impeller which is of modern design, rotates on stainless spindles mounted in the measuring chamber. The impeller is made of self-cleaning synthetic resin. The helix aligns with the pipe axis. The complete metering unit is easily removable from the meter body. And is designed to ensure high flow-rate with the smallest headloss. Versions for warm water up to 90°C and telemetering (complete with a pulse output) are also available.

Liquid Turbine Flow Meters

Read more Turbine Flow Meter Application Case: Demineralized Water.

Low flow turbine flow meter

The small Diameter (small flow) liquid turbine flow meter, is a precision flow measuring instrument,that can be used to measure the flow and total volume of liquids. The structure is explosion-proof and can show the total flow, instantaneous flow and percentage of flow fullness. It is widely used in measurement and control systems in petroleum, chemical, metallurgical, scientific research and other fields. Sensors equipped with sanitary fittings can be used in the pharmaceutical industry.

Turbine flow meter price

Sino-Inst is a Turbine flow meter manufacturer, China. Sino-Inst offers over 10 turbine flow meter products. A wide variety of turbine flow meter options are available to you, such as free samples, paid samples. The price of turbine flow meters are decided by flollowing factors:

  • Pipe diameter;
  • Flow range;
  • Measured medium;
  • Whether it is corrosive;
  • Whether explosion protection is required;
  • Whether it needs local display;
  • Connection method;
  • Measure pressure;
  • Measure temperature;
  • Signal output;
  • Accuracy requirements;
  • Material requirements;

For example, Model DN15 Turbine flow meter’s price is around USD 140.00/pc.

More about: Best Price Turbine Flow Meters From Reliable Manufacturer

Electromagnetic flow meter

A Magnetic flow meter, also called electromagnetic flow meter, mag flow meter, or magmeters. A magnetic flow meter is a volumetric flow meter that works with principle of magnetic technology. Magnetic flow meters do not have any moving parts. An electromagnetic flowmeter consists of two parts: Electrode (sensor) and Transmitter. Installation types of magmeters could be: Compact, remote, insertion.

Magnetic flow meter is ideal for wastewater applications or any dirty liquid which is conductive or water based. Magnetic flow meters are also ideal for applications where low-pressure drop and low maintenance required. A range of liner materials, electrode options, and line sizes accommodate a wide variety of process application.

Extended reading: Industrial Magmeters

How does an electromagnetic flow meter work?

Magnetic flow meters use a magnetic field to generate and channel liquid flow through a pipe.
A voltage signal is created, when a conductive liquid flows through the flowmeter’s magnetic field.
The faster the flow of the fluid, the greater the voltage signal generated.
Electrode sensors located on the flow tube walls pick up the voltage signal. And send it to the electronic transmitter, which processes the signal to determine liquid flow.

More about Magnetic flow meter.

What is Flow Transmitter working principle?

Flow Metering Principles

From the measurement principle, the flowmeter can be divided into Volumetric flowmeters and Mass flwo meters.

VOLUMETRIC FLOWMETERS:

  • Differential Head type
    • Orifice plates
    • Venturi meters
    • Annubar
  • Differential Area type (Rotameters)
  • Electromagnetic flowmeters
  • Ultrasonic flowmeters
  • Turbine flowmeters
  • Vortex flowmeters
  • Positive Displacement Meters

MASS FLOWMETERS:

For different working principle, We offer different types of flow meters, like:

How does a pulse flow meter work?

The frequency signal is converted into a digital signal for display. This is called a pulse flow meter. The pulse is the output signal of the flow meter. It is a pulse output. Now the standard output of most flow meters is 4-20MA, which can also be made into a pulse output.

Turbine flowmeters use the mechanical energy of the fluid to rotate a “pinwheel” (rotor) in the flow stream. Blades on the rotor are angled to transform energy from the flow stream into rotational energy. The rotor shaft spins on bearings. When the fluid moves faster, the rotor spins proportionally faster. Turbine flowmeters now constitute 7% of the world market.

Shaft rotation can be sensed mechanically or by detecting the movement of the blades. Blade movement is often detected magnetically, with each blade or embedded piece of metal generating a pulse. Turbine flowmeter sensors are typically located external to the flowing stream to avoid material of construction constraints that would result if wetted sensors were used. When the fluid moves faster, more pulses are generated. The transmitter processes the pulse signal to determine the flow of the fluid. Transmitters and sensing systems are available to sense flow in both the forward and reverse flow directions.

Where are flow meters used?

Where are flow meters used? Or, What does a flow meter measure?

At industrial sites, meters that measure fluid flow are referred to as flow meters or flow sensors.

It is one of the most important instruments in industrial measurement.

With the development of industry, the accuracy and range of flow measurement requirements are getting higher and higher.

In order to adapt to various purposes, various types of flowmeters have been successively launched,

widely used in oil and gas, petrochemical, water treatment, food and beverage.

Industries such as pharmaceuticals, energy, metallurgy, pulp and paper, and building materials.

  1. Measurement of gas mass flow in industrial pipelines
  2. Smoke flow rate measurement from the chimney
  3. Calciner flue gas flow measurement
  4. Air flow measurement during gas process
  5. Compressed air flow measurement
  6. Gas flow measurement during semiconductor chip manufacturing process
  7. Gas flow measurement in sewage treatment
  8. Gas flow measurement in heating ventilation and air conditioning systems
  9. Flux recovery system gas flow measurement
  10. Measurement of combustion gas flow in a combustion boiler
  11. Gas flow measurement of natural gas, flare gas, hydrogen, etc.
  12. Measurement of carbon dioxide gas flow during beer production
  13. Measurement of gas mass flow in the production process of cement, cigarette and glass factory
  14. Open channel

Sino-Instrument offers over 50 flow meter for flow measurement.

About 50% of these are differential pressure flow meters, 40% is the liquid flow sensor, and 20% are Ultrasonic Level Transmitter and mass flow meter.

A wide variety of flow meters options are available to you, such as free samples, paid samples.

Sino-Instrument is a globally recognized supplier and manufacturer of flow measurement instrumentation, located in China.

Request a Quote

Please enable JavaScript in your browser to submit the form

Electronic Flow Meters

Electronic flow meters are industrial digital flow meters for fluid flow rate measurement. In more cases, people will default that Electronic flow meters are electromagnetic flowmeters.

Electronic flow meters types like Magnetic, Vortex, and Ultrasonic flow meters. Electronic flow meters are suitable for Industrial liquid, water, natural gas, petrol, fuel, air, and more fluid flow. Electronic flow meters convert the monitored fluid flow into electronic signals. Including pulse signal, 4-20mA standard signal, etc.

Sino-Inst offers a variety of  Electronic flow meters for flow measurement. If you have any questions, please contact our sales engineers.

Sino-Inst, the manufacturer of Electronic flow meters. We will answer your various questions about Electronic flow meters.

What is electronic flow meter?

A flow meter is a device used to measure the volume or mass of a gas or liquid. Flow meters are referred to by many names, such as flow gauge, flow indicator, liquid meter, flow rate sensor, flow rate meter, etc. depending on the particular industry.

Electronic flow meters are industrial digital flow meters for fluid flow rate measurement. Electronic flowmeters types like Magnetic, Vortex, and Ultrasonic flow meters.

While magnetic, vortex, and ultrasonic–are neither exclusively nor exhaustively electronic in nature. They do represent a logical grouping of flow measurement technologies.

All electronic flow meters have no moving parts, are non-intrusive, and are made by electronics technology.

Magnetic flowmeters are the most directly electrical in nature, deriving their first principles of operation from Faraday’s law. Vortex meters depend on piezoelectric sensors to detect vortices shed from a stationary shedder bar. And today’s ultrasonic flowmeters owe their successful application to sophisticated digital signal processing.

Read more about: What is a Flow Meter? Types and how does it work?

Featured Electronic Flow Meters

Electronic flow meter working principle

Simply put, the working principle of Electronic Flow Meters is to convert the flow rate of the measured fluid into an electronic signal through the flow sensor component. And can carry out flow rate display and signal output. For example, display instantaneous flow rate, cumulative flow, etc.

As you can see. There are many types of Electronic Flow Meters. Therefore, their accurate measurement principles are different.

Magnetic flow meters use a magnetic field to generate and channel liquid flow through a pipe.

A voltage signal is created, when a conductive liquid flows through the flowmeter’s magnetic field.

The faster the flow of the fluid, the greater the voltage signal generated.

Electrode sensors located on the flow tube walls pick up the voltage signal, and send it to the electronic transmitter, which processes the signal to determine liquid flow.

Let see the video about:

How to Measure Flow with Magnets – (Magnetic Flow Meters)

Video source: https://youtu.be/TR0baWuB6v4

Faraday’s Law

The operation of a magnetic flow meter or mag meter is based upon Faraday’s Law, which states that the voltage is induced across any conductor. As it moves at right angles through a magnetic field, is proportional to the velocity of that conductor.

Faraday’s Formula

E =V x B x D

E = The voltage generated in a conductor

V = The velocity of the conductor

B = The magnetic field strength

D = The length of the conductor

To apply this principle to flow measurement with a magnetic flow meter, it is necessary first to state that the fluid being measured, must be electrically conductive for the Faraday principle to apply.

As applied to the design of magnetic flow meters, Faraday’s Law indicates that signal voltage (E), is dependent on the average liquid velocity (V) the magnetic field strength (B). And the length of the conductor (D) (which in this instance is the distance between the electrodes).

In the case of wafer-style magnetic flow meters, a magnetic field is established throughout the entire cross-section of the flow tube.

If this magnetic field is considered as the measuring element of the magnetic flow meter, it can be seen that the measuring element is exposed to the hydraulic conditions, throughout the entire cross-section of the flow meter.

With insertion-style flow meters, the magnetic field radiates outward from the inserted probe.

Extended reading: Industrial Magmeters

Advantages of using Electromagnetic Flow Meters.

  • High precision and stability
  • Self-check
  • Two-way measurement
  • No pressure loss
  • No moving parts
  • May be for sanitary purposes
  • Large size available
  • Dirty liquid and mixed fructose are ok

Disadvantages of using Magnetic Flow Meters

  • Can not be used to measure gas, steam and liquids containing a lot of gas;
  • Cannot be used to measure liquid media with very low conductivity. The electromagnetic flowmeter cannot measure petroleum products or organic solvents and other media;
  • Cannot be used to measure high temperature media. At present, it is restricted by the lining material and electrical insulation material of the measuring tube of the electromagnetic flowmeter for general industry;
  • The electromagnetic flowmeter is easily affected by external electromagnetic interference.

Extended Reading: Petroleum Flow Meter

A vortex flow meter is a flow measurement device best suited for flow measurements, where the introduction of moving parts presents problems.

They are available in industrial grade, brass, or all-plastic construction. Sensitivity to variations in the process conditions is low, and no moving parts have relatively low wear compared to other types of flow meters.

Vortex flowmeters operate under the vortex shedding principle, where oscillating vortexes occur when a fluid such as water flow past a bluff (as opposed to a streamlined) body.

The frequency that the vortexes are shed depends on the size and shape of the body. It is ideal for applications where low maintenance costs are important.

Industrial size vortex meters are custom built and require appropriate sizing for specific applications.

The Vortex Shedding flow meter detects the vortices, that are created by a process medium going past a bluff body.

The frequency of these vortices can be equated to flow velocity, which, in turn, is used to calculate the volumetric flow rate.

The integral temperature sensor is used in saturated steam service, to determine the operating conditions and specific volume of the steam being measured.

The steam table incorporated into the electronics then calculates the flow of energy of the stream flowing through the meter.

The optional pressure sensor can be used for similar calculations, for gasses and superheated steam. Intelligent Signal Processing (ISP) provides stable readings, free of external influences.

Why Generally Choose 4-20ma Output?

Ultrasonic flowmeters use sound waves to determine the velocity of a fluid flowing in a pipe.

At no flow conditions, the frequencies of an ultrasonic wave transmitted into a pipe, and its reflections from the fluid are the same.

Under flowing conditions, the frequency of the reflected wave is different, due to the Doppler effect.

When the fluid moves faster, the frequency shift increases linearly. The transmitter processes signals from the transmitted wave, and its reflections to determine the flow rate.

Generally, an ultrasonic flow meter is a device, that uses ultrasound to measure the velocity of liquid flow. That helps in determining the volume of liquid flow also.

The ultrasonic flow meters are made using ultrasonic transducers, which are clamped to the external surface of a pipe, to generate the ultrasonic pulses through the pipe.

When the liquid flows inside the pipe, it creates the time difference in the pulses, and these are examined to calculate the accurate flow velocity of the liquid.

There are many advantages of using the ULTRASONIC flow meters which include:

  • The electronics in the ultrasonic flow meter includes ultrasonic flowmeter detector which compensates and adapts to the changes in the profile of the flow, type of the liquid and material of the pipe.
  • A portable ultrasonic flow meter converter can be used as a direct method to determine the flow rates effectively when compared to the other flow systems.
  • Ultrasonic flow meter converter is inexpensive to use and maintain when compared to the other mechanical flow meters as they are no moving parts in these flow meters.
  • Their design is highly sophisticated and they do not obstruct the liquid flow, so they can be used for sanitary, corrosive and abrasive liquids.

These are the advantages of the ultrasonic flow meters and there are many disadvantages of the Ultrasonic flow meter which include:

  • The main disadvantage of the ultrasonic flow meter is the cost. The cost of the flow meter is very high when compared to the other types of mechanical flow meters.
  • The ultrasonic flow meters are sophisticated when compared to the mechanical flow meters, so it needs experts to repair and maintain the flow meters.

These are the advantages and disadvantages of ultrasonic flow meters.

Fuel flow meters, also known as turbine flow meters, are the main types of speed flow meters. A freely rotatable impeller is installed in the fluid-flowing pipe. When the fluid passes, its motion can make the impeller rotate. The larger the fluid flow rate, the larger the kinetic energy, and the higher the impeller speed.

The fluid flow can be determined by measuring the number of revolutions or the number of revolutions of the impeller.

Extended Reading: Fuel Flow Meters for Diesel-Marine fuel-Industrial oil

Perhaps you are not clear about the principle of Electronic Flow Meters. Don’t want to know more about it. Just want to find the applicable Electronic Flow Meters. Then you can start from your measuring medium.

Electronic flow meter for water

A Digital Water flow meter is a flow meter that can display the water flow rate, and have the output for the flow rate. Like 4-20mA output, HART, RS 485, and so on. Digital Water Flow Meter is also called Electronic Water Flow Meter. Digital Water Flow Meter is widely used in industrial water and household water measurement. Most of the Sino-Inst flow meters are digital water flow meters. Like the electromagnetic flowmeter, Portable ultrasonic flow meter, Turbine flow meter…..

Read more Digital Water Flow Meters

Electronic flow meter for air

Digital gas flow meters are flow meters used to monitor the gas flow rate or mass. Digital gas flow meters are designed to measure different types of gases. Like Air, N2, O2, CO2, and more.

Digital gas flow meters can measure the flow of a wide variety of gases. According to measurement principles, there can be positive displacement gas flow meters, velocity gas flow meters, and mass gas flow meters. How to choose the right Digital gas flow meters? We will discuss in detail next.

Read more Digital gas flow meters for Sale

Electronic flow meter for oil

Industrial oil flow meters measure the volume or mass of oil. Can realize the mutual conversion of volume and mass.

The main industrial oils are hydraulic oil. Gear Oil. Turbine oil. Compressor oil. Refrigeration oil. Transformer oil. Cylinder oil, heat treatment oil, heat transfer oil, etc. Of course, edible oil can also be produced in the industry. In addition, there are greases with lubricating oil as base oil and thickening agent.

Therefore, whether it is a company that uses, trades, or produces oil, it needs to accurately measure the oil flow.

There are many common oil flow meters, such as turbine flow meters, positive displacement flow meters, gear flow meters, mass flow meters, etc.

Then, we need to choose a suitable flow meter that meets the measurement and budget according to different working conditions.

Read more Industrial Oil Flow Meters

What are the different types of flow meters?

Flowmeter types: Generally speaking, we will classify flow meters according to their working principles.

Flow Metering Principals

  • Differential Pressure Flowmeters
  • Velocity Flowmeters
  • Positive Displacement Flowmeters
  • Mass Flowmeters
  • For Open Channel Flowmeters – weirs, flumes, submerged orifices, current meters, acoustic flow meters and more

For different working principles, We offer different types of flow meters, like:

  • Differential Pressure Flow Meters
  • Orifice Plate
  • Venturi Tube
  • Flow Nozzles
  • The Sonic Nozzle – Critical (Choked) Flow Nozzle
  • Calorimetric Flowmeter
  • Ultrasonic Doppler Flowmeter
  • Positive Displacement Flowmeter
  • Variable Area Flowmeter or Rotameter
  • Velocity Flowmeters
  • Pitot Tubes
  • Electromagnetic Flowmeter
  • Turbine Flowmeter
  • Vortex Flow Meter
  • Thermal Flowmeter
  • Coriolis Flowmeter
  • Mass Flowmeters
  • Open Channel Flowmeters

Extended reading: Gas Rotameter Tips

How to choose your flowmeters?

Important factors when selecting flow metering devices are:

  • Measured medium
  • Accuracy
  • Cost
  • Flow rate range
  • Pperating requirements
  • Maintenance
  • Lifetime
  • Lead time

These factors are more or less related to each other. For example – the cost of flow meters increases with accuracy and lifetime quality. Read more about: What Is GPM In Flow Meter?

More about Electronic Flow Measurement Technology

Sino-Inst offers over 50 Electronic flow meters for flow measurement. About 50% of these are differential pressure flow meters, 40% is the liquid flow sensor, and 20% are Ultrasonic Level Transmitter and mass flow meters.

A wide variety of Electronic flow meters options are available to you, such as free samples, paid samples. Sino-Inst is a globally recognized supplier and manufacturer of flow measurement instrumentation, located in China.

Request a Quote

Please enable JavaScript in your browser to submit the form

Compressed Air Flow Meter

Compressed Air Flow Meter, is the digital flow meter work for the air compressor. Air consumption is an important info for industrial inline gas flow pipe. According to the measurement conditions, compressed air flow meter could be different types. Thermal mass flow meters, Ultrasonic flow meters, Vortex flow meters, Turbine flow meters. And the differential pressure flow meters (Orifice plate ) are also suitable for compressed air. With the Pressure and Temperature compensation. Sino-Inst’s compressed air flow meters are more affordable and complete.


RFQ NOW

Featured Compressed Air Flow Meter


Thermal mass flowmeters

 

Gas Turbine Flow Meters

 

Industrial Vortex Flow Meter

Compressed air flow meter working principle

There are a variety of measurement principles can be used to measure compresses gas.

Turbine gas meters are robust meters, used to measure gas consumption. In gas distribution, transmission, industrial plants and for commercial users. The meter tracks the flow rate continuously, offers little resistance to flow, and has a unique cartridge design that allows removal of all internal parts as one assembly.The meter also exhibits little sensitivity to gas density above two atmospheres pressure.The low inertia of the rotor and vee bearings, allows overhanging of the meter to twice its rated capacity, without damage for intermittent flow variations.  Orifice plates and venturi tubes rely on detecting the differential pressure across a restriction in the pipe,and this pressure is directly proportional to the media velocity. Given knowledge of the pipe dimensions and media characteristics,a differential pressure instrument can give a reading directly in flow units. The accuracy of these systems are reliant on very fine tolerance machining of the orifice or venturi and the pressure drop incurred,through the installation of these devices may not suit all situations. These can be highly accurate and reliable but are expensive and complicated to install and maintain. Pitot tube systems work on a very similar principle and remove the issue of the pipe restriction,as there is only a small diameter tube inserted at right angles to the flow. These can be inserted through ball valves, making removal for service or calibration very simple. This method does not need perfectly dry and pure gases to be accurate,and is very tolerant of wet gases and contaminants which makes it ideal for measuring in difficult places. Such as compressor outlets. Vortex meters place a bluff restriction in the pipe,that causes vortices to form alternately on the 2 rear edges. Sensors are used to detect the formation of these vortices, the frequency of which is directly proportional to the flow rate. These instruments are accurate but again introduce a large restriction into the pipe,and are often employed on steam applications. 

Extended Reading: Digital air flow meters

What about Thermal Mass?

Thermal mass meters and calorimetric flow sensors sense the cooling effect on a heated element,which is directly proportional to the mass flow rate rather than the volumetric flow rate. This removes the subsequent calculations needed to determine mass flow rate,using other methods of flow measurement, and there is no pressure or temperature compensation necessary.The actual sensing tips are small and thus the restriction placed,in the pipe produces very little back pressure, making this method ideal for very low and very high flow rates.Thermal mass meters are available in a range of accuracies and are ideal for dry, clean gas flow measurement. Some designs have all stainless steel wetted parts making them better suited to contaminated or corrosive gases,which would damage the exposed sensing elements of unprotected designs. They are not suitable for wet gases or steam. For those applications a pitot tube design or possibly a vortex meter would be the better choice. Thermal mass is also an excellent principle for use in flow switches,as there are no moving parts in the media and the sensor produces very little back pressure due to its minimal size. These flow switches are very sensitive and some models can be used to determine flow direction as well as flow/no flow.

Know More about Flow Meters


Gas mass flow meter

Gas mass flow meter, are the thermal mass flow meter, which is best choice for gas flow rate measurement. Based on the principle of thermal diffusion, Gas mass flow meter measure the flow rate of gas. Like: air flow, nitrogen, natural gas flow rate.

Digital water flow meters

Digital Water flow meter, means flow meter that can display water flow rate, and have the output for the flow rate. Like 4-20mA output, HART, RS 485, and so on. 




Nitrogen flow meter

Nitrogen Flow Meter, is the flow meter that can measure the flow rate of nitrogen gas. Sino-Instrument is the nitrogen flow meter supplier in China. Vortex flow meter, is the common choice for gas flow rate inline measurement instrument. Like the air, nitrogen gas, steam, oxygen…..

Sino-Instrument is a well-known Exporter, Supplier,

Trader and Service Provider of Flow Measurement Instrument,

LEVEL METERSPRESSURE TRANSMITTERS, AMR Solution, etc.

Our presented products are used in commercial places for various purposes.

These products are extremely admired in the market due to their reliable performance,

compact design, sturdy nature, easy to fit, longer operational life,

low maintenance, and low prices.

 

Request a Quote

Please enable JavaScript in your browser to submit the form

Gas Mass Flow Meter

Gas mass flow meters are very important in some important industrial fields. This kind of equipment installed in pipelines can detect gas. The gas mass flowmeter manufacturer introduced the task of monitoring the flow rate in the pipeline system.

Featured Gas mass flow meters

Gas mass flow meter types

It uses mechanical equipment measuring components to continuously divide the fluid into separate known parts of the volume. The total flow of the fluid volume is measured according to the frequency of repeatedly filling and draining part of the volume of the fluid in the measuring chamber.

Read more about Mass Flow Rate vs Volumetric Flow Rate

It is a kind of variable total area flowmeter. In a vertical tapered tube that expands from bottom to top. The force of the floating ball with the annular cross-section is borne by the hydrodynamic force. In turn, the floating ball can be freely moved in the tapered tube. Raise and lower.

Extended reading: Gas Rotameter Tips

It is an instrument that measures the total flow based on the gas pressure caused by the flow detection device installed in the pipeline, the known fluid standard and the specifications of the inspection room and the pipeline.

A non-streamlined vortex generator is placed in the fluid. The fluid is alternately separated on both sides of the generator to release two series of standard overlapping vortex meters.

Extended reading: 5 matters to pay attention to when choosing threaded Vortex Nitrogen Gas Flow Meter

It is a key type of rate flow meter. It uses a multi-leaf motor rotor (turbocharger) to experience the average water flow of the fluid. Then it calculates the total flow or total output.

A meter that measures the total flow rate based on the efficacy of the fluid fluidity on the ultrasonic beam (or ultrasonic single pulse).

The thermal flowmeter sensor includes 2 sensing technology components. A speed sensor and a temperature sensor. They compensate and calibrate the gas temperature changes fully automatically.

The electric heater part of the instrument heats the speed sensor to a certain time constant higher than the temperature of the working condition. A stable temperature difference is generated between the speed sensor and the sensor that measures the temperature of the working condition.

When the temperature difference does not change, the kinetic energy consumed by the electric heater. It can also be said that the heat dissipation value is proportional to the mass flow rate of the passing gas. It is suitable for the measurement of single gas and a fixed proportion of multiple gases.

The basic principle is to use the Coriolis force caused by the fluidity of the fluid in the vibrating tube. The force can be measured immediately or indirectly to obtain the fluid mass flow.

Extended reading: Liquid Mass Flow Meter

How To Reduce The Effect Of Pressure On The Mass Flow Meter?

Further reading: Industrial LPG/Propane flow meter

Gas mass flow meter Applications

  1. Gas quality flow measurement and operation for heating furnace and cracking furnace;
  2. Petrochemical equipment, oil production plant, torch gas quality flow measurement;
  3. Air index flow measurement and control for combustion furnace; radon mass flow and control for gas turbine generator;
  4. Food industry and beverage gas mass flow and control;
  5. Hydrogen mass flow control in waterworks;
  6. High-purity gas quality flow measurement when manufacturing semiconductor materials;
  7. Quality flow measurement of metal catalysts and organic chemical preservatives;
  8. Pump maintenance and operation, pump tightness, and grease pool leakage inspection;
  9. Central air-conditioning control system;
  10. Mass flow measurement of instrument gas, process gas, N2, etc.
  11. Gas detector, atmospheric sampler
  12. Leak detection
  13. Gas distribution system software
  14. Laboratory gas measurement
  15. Medical applications
  16. Solid-State Battery
  17. Gases used: Air, O2, N2, He, Ar, CO2, H2, CH4, C3H8, N2O, SF6, C3H6, CO, C4H10, and most of the gases.

Extended reading: Food grade flow meters for Food & Beverage industry

Read more about: Coriolis Mass Flowmeter Working Principle

Common gas flow meters include thermal mass flow meters, vortex flow meters, precession vortex flow meters, and gas ultrasonic flow meters. 

Thermal Mass Flow Meter can directly measure the mass flow of various gases. Unaffected by changes in viscosity, density, temperature, or pressure.

A thermal Mass Flow Meter is a true mass flow meter. No temperature and pressure compensation is required. Thermal gas mass flow meters are designed based on the principle of thermal diffusion. Including natural gas, coal gas, liquefied gas, flare gas, argon, carbon dioxide and other mixed gas flow measurement.Previous

Read more.

A natural gas flow meter is mainly used for inline measurement of natural gas flow. The natural gas flow meter is mainly used for industrial production and trade settlement.

At present, the flowmeter products used for natural gas flow measurement roughly include: gas waist wheel flowmeter, gas turbine flowmeter, precession vortex flowmeter, thermal mass flowmeter, vortex flowmeter, ultrasonic flowmeter and orifice flowmeter Wait. Let’s make a simple comparison on the use of these flow meters.

Read more.

LPG flow meter is used for flow measurement of liquefied petroleum gas. The flow measurement of LPG is very important in industrial production, transportation and trade settlement.

LPG gas (Liquefied petroleum gas) is a kind of hydrocarbon with propane and butane as its main components. LPG is used for heating, motor fuel, industrial applications and in agriculture. LPG can be in a gas or liquefied state. Different type industrial LPG flow meters with accurate and reliable performance. Such as thermal dispersion flow meter, Coriolis flow meter, gas turbine flow meter, vortex flow meters.

Read more LPG flow meters.

There are many types of Nitrogen gas flow meters. There are three types of flow meters commonly used to measure nitrogen. Precession vortex flowmeter, gas vortex flowmeter, thermal gas mass flowmeter. When selecting a model, it is necessary to select a suitable model and specification according to the parameters and cost that can be provided on-site.

There are 6 types of commonly used nitrogen flow meters:

Vortex flowmeter

Intelligent precession vortex flowmeter

Orifice flowmeter

Gas mass flow meter

Coriolis mass flowmeter

Rotameter flow meter

Of course, which type of nitrogen flowmeter to use. Please make further confirmation according to your actual needs.

Read more Nitrogen Gas-Liquid Nitrogen Flowmeters.

Thermal mass flow meter

What is a Thermal Mass Flow Meter?

A thermal gas mass flow meter is a flow meter that can detect the mass flow of gas without temperature and pressure compensation.

Thermal Mass Flow Meter Unaffected by changes in viscosity, density, temperature, or pressure. Thermal mass flow meters are designed based on the principle of thermal diffusion.

Including natural gas, coal gas, liquefied gas, flare gas, argon, carbon dioxide, and other mixed gas flow measurement.

Read more about: Tips for Thermal Mass Flow Meter|Better Industrial Gas Meter

Gas mass flow meter working principle

The thermal flowmeter is a flowmeter designed based on the principle of thermal diffusion.

That is, when the fluid flows through the heat-generating object, the heat loss of the heat-generating object is proportional to the flow rate of the fluid.

The sensors of the series flowmeter have two standards RTD,

one for the heat source, and one for measuring the temperature of the fluid.

When the fluid flows, the temperature difference between the two is linear with the flow rate,

and then the relationship is controlled by microelectronic control technology.

Converted to a linear output that measures the flow signal.

Read more about:

Gas Mass Flow Controller

The gas mass flow controller is based on the principle of thermal mass flow measurement. With control valve. The Micro Gas Flow Controller (MFC) is used to precisely measure and control the mass flow of gas. Guess you like: Gas … Continue reading

Air mass flow meter VS Controller

Air mass flow meter (abbreviated as MFM) is used for precise measurement of gas mass flow.A gas mass flow controller (abbreviated as MFC) is used for precise measurement and control of gas mass flow. Related products What is a mass … Continue reading

Gas Thermal Mass Flow Meter

You may like: More Featured Industrial Gas Flow Meters FAQ Sino-Inst offer over 10 Thermal Mass Flow Meters, with Best Price. A wide variety of Thermal Mass Flow Meters options are available to you, such as free samples, paid samples. … Continue reading

Advantages of gas mass flowmeters

(1) The gas mass flow meter can be used at normal temperature and pressure or under high pressure. And this product can directly measure the desired data. No pressure compensation is required. No flow compensation is required. This is Unmatched by other products.

(2) It can work normally at room temperature or 100 degrees or even higher temperature. It does not need any temperature compensation. It can be effectively and directly measured.

(3) The gas mass flow meter has a relatively wide range. Generally speaking, it can take into account both small flow and large flow measurement. It is especially suitable for those large-caliber measurements.

(4) The flow resistance of the gas mass flowmeter is basically declining. The ability to resist media corrosion is relatively strong, and the measurement accuracy is relatively high.

(5) When the gas mass meteor meter is actually outputting the signal, it will take into account the situation of each signal, and it can be displayed by remote transmission, which is convenient for cooperating with other meters. It can also be effectively realized after this. Multi-flow records can be automatically accumulated, and data can be easily searched anytime and anywhere.

(6) The gas mass flowmeter is more convenient to install and easy to maintain. It can play a variety of anti-vibration functions.

(7) There are many applications of gas mass flow meters, which can be used in public works. They can be used well in the supervision system of water treatment. They can also be used in oil or natural gas projects, which can be used for energy exchange.

FAQ

A gas flow meter is an instrument for measuring the flow of gas. Installed in the pipeline to record the amount of gas flowing through.

Can measure gas, air, nitrogen, acetylene, phosgene, hydrogen, natural gas, nitrogen, liquefied petroleum gas, hydrogen peroxide, flue gas, methane, butane, chlorine, fuel gas, biogas, carbon dioxide, oxygen, compressed air, argon Gas, toluene, benzene, xylene, hydrogen sulfide, sulfur dioxide, ammonia, etc.

Extended reading: Cryogenic Flow Meters | Liquid Nitrogen-Liquid Oxygen

A propane flow meter refers to a flow meter that can measure the volume or mass flow of propane gas. Also often called LPG gas flow meter.

Generally, flanges are used to install propane gas flow meters online. You can refer to more details: New Industrial LPG/Propane flow meter-Precession Vortex

Unit of gas flow: cfm. Square refers to 1 cubic meter of gas. Strictly speaking, square should be a unit of volume, not a unit of flow.

CMM is a commonly used medium-scale flow unit, per minute.

During the unit British period, the filter passes through a certain volume of air flow. We generally use m3/h air volume unit. Foreign countries also use m3/h air volume unit cfm (cubic feet per minute). That is, ft3/min cubic feet/minute.

Commercial conversion is: 1cfm≈1.7m3/h.

Most of our gas flow meters have a local digital display. Can display the instantaneous flow of gas, cumulative flow, etc.

Of course, there is also a pointer display. Then you need to read the flow value according to the dial scale.

A wide variety of industrial flow meter options are available to you, such as free samples, paid samples.

Sino-Inst offers over 10 Gas mass flow meters, with the Best Price.

All of our flow meters can work with the AMS NEW TREX.

About 13% of these are magnetic flow meters, 14% are Insertion Magnetic Flow Meter, 25% are Venturi flow meters, 13% are Handheld ultrasonic flow meters, and others are Liquid Turbine Flow Meters.

Sino-Instrument is mass flow meter supplier, located in China. Mass flow meter products are most popular in North America, Mid East, and Eastern Europe.

The United States, and India, which export 99%, 1%, and 1% of ultrasonic level transmitters respectively.

You can ensure product safety by selecting from a certified supplier, with ISO9001, ISO14001 certification.

Request a Quote

Please enable JavaScript in your browser to submit the form

Nitrogen Gas-Liquid Nitrogen Flowmeters

Nitrogen Flowmeters are a type of flow meter that can measure the flow of nitrogen or liquid nitrogen. The common nitrogen flow rates are nitrogen and liquefied nitrogen. Nitrogen is often referred to as an inert gas. Used in metal processing in some inert atmospheres. When it is liquid, it is a common reagent for cooling, cooling, and freezing. Optimize your nitrogen system and save costs. Therefore, it is very important to accurately measure the nitrogen flow rate.

Nitrogen flowmeters are important to different industries. Inline Flow Measurement of Nitrogen needs to purchase the correct flow meter.

Please follow the purchasing guide below. You will find your most suitable Nitrogen flowmeter!

First, let’s take a look at nitrogen.

Flow Measurement of Nitrogen

Nitrogen is required in many processes of the chemical and pharmaceutical industry; predominantly as protective gas, to prevent the occurrence of explosive atmospheres。

Such as when handling dusty products or solvents.

If your work requires you to use nitrogen, having a flow meter installed on your tank is a great way to save some money.

These indicators let you know whether gas is moving through the line, often via the use of a levitating ball, a pressure gauge, or other visual cues.

These options are simple to use and reliable, making them must-haves for welders, HVAC technicians, and more.

Guess you like Industrial oxygen flow meter

Next comes the most important question:

Nitrogen(N2) Flow Meter Types

There are many types of Nitrogen gas flow meters. There are three types of flow meters commonly used to measure nitrogen. Precession vortex flowmeter, gas vortex flowmeter, thermal gas mass flowmeter. When selecting a model, it is necessary to select a suitable model and specification according to the parameters and cost that can be provided on-site.

There are 6 types of commonly used nitrogen flow meters:

If you need to measure the volume flow (m3/h, dum/s), it is best to use a vortex flowmeter. The accuracy is quite high and the price/performance ratio is good. However, when measuring with a vortex flowmeter, pay attention to the measuring range.

The vortex flowmeter directly measures the volume flow of gas and liquid. It is necessary to add temperature and pressure measuring sensors and totalizers to calculate mass flow.

This is a new type of gas flow meter. The flowmeter integrates flow, temperature, and pressure detection functions. And can automatically compensate for temperature, pressure and compressibility. It is an ideal instrument for gas measurement in petroleum, chemical, electric power, metallurgy and other industries. It is also a common choice for nitrogen flowmeters.

For volume flow measurement, you can also use differential pressure flow meters, orifice flow meters, Verabar, and Annubar flow meters. However, the accuracy is lower and the price is higher. Its advantage is that it can measure the flow of gas-liquid two-phase media. For example, due to gas liquefaction or gas-liquid two-phase formation under high pressure.

Orifice plate flowmeter, orifice plate as a throttling element, equipped with a differential pressure transmitter. The volume flow can be calculated. To convert to mass flow, temperature and pressure sensors and totalizers must also be added.

Read more about: Inline gas flow meter

If it is a mass flow measurement, a gas mass flow meter can be used. Thermal gas mass flow meter directly measures the mass flow of common gases, including nitrogen.

Direct measurement of the mass flow of gas and liquid can be used to measure nitrogen, which is more expensive.

Extended reading: Liquid Mass Flow Meter

A Rotameter flow meter is a variable area flow meter based on float position measurement. It is suitable for liquid and gas volumetric flow measurement and control.

The nitrogen flowmeter we designed is easy to use, reasonably priced, and fully functional. You can use our flow meters to measure compressed air, nitrogen, and industrial gases.

Extended reading: Gas Rotameter Tips

Of course, which type of nitrogen flowmeter to use. Please make further confirmation according to your actual needs.

Guess you like: Gas Mass Flow Meter

Extended reading: Cryogenic Flow Meters | Liquid Nitrogen-Liquid Oxygen

Featured Nitrogen Gas Flowmeter

There are 4 types of flow meters commonly used to measure the mass flow of nitrogen:

Thermal gas mass flow meter. Directly measure the mass flow of common gases, including nitrogen.

Coriolis mass flowmeter. Directly measure the mass flow of gas and liquid. It can be used to measure nitrogen, which is more expensive.

The vortex flowmeter directly measures the volume flow of gas and liquid. It is necessary to add temperature and pressure measuring sensors and totalizers to calculate the mass flow.

Orifice flowmeter. The orifice plate is used as a throttling element and is equipped with a differential pressure transmitter. The volume flow can be calculated. To convert to mass flow, temperature and pressure sensors and totalizers must also be added.

The above comparisons. Recommend thermal gas mass flow meter. The price is moderate, the installation and maintenance are simple, and the measurement is accurate.

Cryogenic Liquid Nitrogen Flowmeters

Liquid nitrogen refers to liquid nitrogen. Liquid with extremely low temperature. In industrial production, liquid nitrogen can be used as a deep refrigerant. The low-temperature turbine flowmeter is used as a liquid nitrogen flowmeter, which can work at a low temperature of -196°C (-320.8 °F).

Liquid Nitrogen FlowMeter’s Turbine sensor structure at ultra-low temperature (-196℃) is made of special customized material, and it is equipped with a low-temperature resistant amplifier. Realize the instantaneous and cumulative flow monitoring of liquid nitrogen.

  1. Nominal diameter:
    Common type (0.5~300) mm;
    Anti-corrosion type (6~100) mm
    Insertion type (80~600)mm
  2. Medium temperature:
    Ordinary type (-20~80)℃
    High temperature type (-20~120)℃
    Ultra-low temperature type (-196~80)℃
  3. Ambient temperature: (-20~55)℃;
  4. Accuracy: ±0.2%, ±0.5%, ±1%;
  5. Detector signal transmission line system: three-wire voltage pulse (three-core shielded cable);
  6. Power supply: voltage: 12V±0.144V, current: ≤10mA;
  7. Output voltage amplitude: high level ≥ 8V, low level ≤ 0.8V;

Gear flow meters are also a good choice for small-caliber liquid nitrogen measurement.

Gear flow transmitter is a type of positive displacement flow transmitter. It is a high-precision transmitter for measuring volume flow.

With the flow of the medium, the gears mesh and rotate. Under the action of the fluid flow, a pressure difference is formed at both ends of the instrument inlet and outlet. There is no need for a power supply. A pair of gears rotate freely. The cavity between the gears is filled with liquid. Discharge and measure the number of revolutions of the gear to know the flow of liquid and liquid flowing through the instrument.

  • High pressure resistance (1.0-45MPa)
  • High and low temperature resistance (-196℃-200℃)
  • Can measure various viscous media
  • High precision and repeatability
  • Pulse output/analog output optional
  • Wide range ratio (1:100)
  • Wide measuring range
  • Strong anti-corrosion and anti-fouling ability (acid and alkali)

Extended reading: liquid nitrogen level measurement

Case: Vortex flowmeter used for nitrogen gas flow measurement

The vortex flowmeter works according to the Karman vortex principle. Each pulse or certain current signal output by the meter represents a certain volume of the measured medium. The total number of pulses output during a period of time or the integral of the analog current quantity will represent the sum of the flow of the medium flowing in this period. That is, the instantaneous flow and cumulative flow we often say.

The vortex flowmeter measures a wide range of media, and it can measure gas, liquid and steam. It has a high working temperature and can withstand 350 degrees high temperature. No moving parts, safe and reliable measurement, no wear. The watch body is made of stainless steel, which is corrosion resistant and has a long service life.

Today we are mainly talking about the vortex flowmeter used for the measurement of nitrogen flow.
Give an example to illustrate:

A user measures nitrogen. The pipe diameter is 100mm. The usual flow rate is 950m3/h. Temperature and pressure.
The temperature and pressure of the site working conditions are not high. The flow rate is also within the measurable range of the vortex flowmeter.
It is understood that the user’s installation site environment is also better without major vibration or interference. Therefore, the user uses a nitrogen flowmeter, that is, a vortex flowmeter. The specific parameters are as follows:

  • Measuring medium: nitrogen
  • Medium temperature: normal temperature
  • Working pressure: normal pressure
  • Flow range: 120-1200m3/h
  • Connection method: flange pipe type
  • Installation direction: horizontal installation
  • Body material: 304 stainless steel
  • Sensor material: 304 stainless steel
  • Resistance body material: 304 stainless steel
  • Display mode: on-site LCD display
  • Power supply mode: 24VDC
  • Pressure rating: 1.0MPa

Vortex flowmeter functions:

  1. On-site LCD displays instantaneous flow and cumulative flow;
  2. Output 4-20mA signal output;
  3. The secondary instrument display can be selected, and it can be used in conjunction with PLC, DCS and other computer control systems;
  4. With temperature and pressure compensation, the accuracy is better;
  5. Can be connected to RS485 communication protocol;
  6. Optional battery power supply and power supply power supply;
  7. There are multiple connection options such as pipe type, plug-in type, threaded connection, and clamp type.

Features of vortex flowmeter:

  1. The nitrogen flowmeter has no moving parts, no wear, dirt resistance, no mechanical maintenance, and long service life;
  2. The overall structure design of the instrument is reasonable, the dynamic measurement range is wide, and the pressure loss is small;
  3. The measurement is not affected by temperature and pressure and is resistant to high temperatures. High pressure.

Vortex flowmeter installation conditions:

  1. There is a straight pipe section at 15-20D. Downstream straight pipe section 5-10D;
  2. Ensure that the medium is full of the pipeline;
  3. Try not to install it in a place with strong vibration or interference. If it must be installed in an environment with vibrations, shock absorption measures should be taken.

FAQ

Flow Metering Principles

  • Differential Pressure Flowmeters
  • Velocity Flowmeters
  • Positive Displacement Flowmeters
  • Mass Flowmeters
  • For Open Channel Flowmeters – weirs, flumes, submerged orifices, current meters, acoustic flow meters and more

For different working principles, We offer different types of flow meters, like:

  • Differential Pressure Flow Meters
  • Orifice Plate
  • Venturi Tube
  • Flow Nozzles
  • The Sonic Nozzle – Critical (Choked) Flow Nozzle
  • Calorimetric Flowmeter
  • Ultrasonic Doppler Flowmeter
  • Positive Displacement Flowmeter
  • Variable Area Flowmeter or Rotameter
  • Velocity Flowmeters
  • Pitot Tubes
  • Electromagnetic Flowmeter
  • Turbine Flowmeter
  • Vortex Flow Meter
  • Thermal Flowmeter
  • Coriolis Flowmeter
  • Mass Flowmeters
  • Open Channel Flowmeters

Important factors when selecting flow metering devices are:

  • accuracy
  • cost
  • legal constraints
  • flow rate range
  • head loss
  • operating requirements
  • maintenance
  • lifetime

These factors are more or less related to each other. For example – the cost of flow meters increases with accuracy and lifetime quality.

Read More about: Choose the most suitable Inline flow meter

You may like:

Fluid Flow Meters

Fluid Flow Measurement Devices Fluid Flow Meters measure the amount of liquid, gas, or steam passing…

Inline water flow meters

Featured inline water flow meters Strap on flow meter X3  External clamp-on flow sensor. Easy to…

Sino-Inst is a well-known Exporter, Supplier, Trader, and Service Provider of Nitrogen flowmeters. Sino-Inst offers over 50 Nitrogen flowmeters for flow measurement. About 50% of these are differential pressure flow meters, 40% are the vortex flow sensor, and 20% are the gear flow meter and mass flow meter.

A wide variety of Nitrogen flowmeters options are available to you, such as free samples, paid samples.

Sino-Inst is a globally recognized supplier and manufacturer of flow measurement instrumentation, located in China.

Industrial flow meters

Flowmeters for Industrial Flow Measurement

The industrial flow meter is one of the most important instruments in industrial measurement. In industrial sites, instruments that measure fluid flow are collectively referred to as flow meters or flow meters. There are very many kinds of flow meters. Based on years of experience, Sino-Inst has compiled the following information. Hope it can help you choose the right industrial flow meter.

Flow Measurement is the process of measuring fluid in your plant or industry. Sino-Inst offers industrial flow meters, with local LCD reading, transmitter, and optical set points. You can measure flow through a variety of different devices, such as Coriolis, differential pressure, vortex, magnetic, ultrasonic, turbine, and positive displacement meters. Industries like: gas flow, airflow, wastewater ( sewage ), pipe (like 4 inches), and etc.

If you need to know the flow rate in you pipe, or river, that when you need a flow meter. So, flow meter is the instrument that can finish the flow measurement.

Flowmeters consist of a primary device, transducer and transmitter.

The transducer senses the fluid that passes through the primary device.

The transmitter produces a usable flow signal from the raw transducer signal.

These components are often combined, so the actual flowmeter may be one or more physical devices.

Different types of flow meters are available for different applications, and depending upon the requirement, a careful selection of flow meters is made.

For e.g., we prefer vortex flow meters to flow steam flow measurement. And we like the ultrasonic flow meters for non-contact pipe flow measurement.

Industrial flow meters Types

Magnetic Flow Meters

Magnetic flow meter is also called electromagnetic flow meter, mag flow meter or magmeter. Suitable for the measurement of conductive liquids.

Turbine Flow Meters

Turbine flow meters are velocity flow meters, also called impeller flow meters. Used to measure the instantaneous flow and cumulative flow of liquids and gases.

Vortex Flow Meters

Vortex flow meter, also called Vortex shedding flow meter. Vortex Flow Meter is suitable for flow measurement of steam and various liquids and gases.

Precession Vortex Gas Flowmeter

Precession vortex flowmeter is a new type of gas flowmeter. It can be used for the measurement of natural gas, propane, air, nitrogen and other gases.

Ultrasonic Flow Meters

The ultrasonic flow meter measures the liquid flow rate quickly and effectively. There are two types of ultrasonic flowmeter technology: Doppler frequency shift and transit time.

Ultrasonic Gas Flow Meters

Ultrasonic Gas Flow Meter uses the principle of measuring the transit time of ultrasonic waves in the pipeline. Ultrasonic Gas Flow Meter is an ideal choice for various gas measurements.

Differential Pressure Flow Meters

Differential Pressure Flow Meter is also called DP flow meter. Differential pressure flow meters use the principle of differential pressure to measure the flow of liquid, gas and steam.

Volumetric Flow Meters

Volumetric Flow Meter, as a mechanical flow meter, is also called Positive displacement flowmeter. It can measure the volume flow of high viscosity and corrosive fluids.

Mass Flow Meters

Mass flow meter directly measures the mass flow of the medium passing through the flow meter. It can also measure the density, temperature and viscosity of the medium.

INDUSTRIES

Sewage flow meter, also known as waste water flow meter. The sewage flow meter measures the flow of various sewages in pipes and open channels. Common sewage flow meters are magnetic flow meters, non-contact ultrasonic flow meters, etc.

Industries like the waste water, river water, industrial gas.

Read more about: Sewage Flow Meters

The air conditioning system is a control system that includes temperature, humidity, air clarity and air circulation, and is called HVAC (: Heating, Ventilation, Air-conditioning and Cooling).

The principle is similar to that of an air conditioner supplying cool air, heating air or dehumidification. The use of refrigerant under the action of the compressor. Produces evaporation or condensation. Then trigger the evaporation or condensation of the surrounding air, in order to change the purpose of temperature and humidity.

Air mass flow meter & Controller is commonly used in HVAC industry.

Read more about:

Air mass flow meter VS Controller

Digital air flow meters

A chilled water flow meter refers to a flow meter that can be used to measure low-temperature water. Common chilled water flow meters include electromagnetic flow meters, turbine flow meters, and ultrasonic flow meters. Used in the condensing system, chiller, or HVAC.

Read more about: Chilled Water Flow Meter

Clean Water can be measured using a variety of flow meters. Commonly used are electromagnetic flow meters and ultrasonic flow meters, etc.

Read more about:

Extended reading: Industrial Magmeters

The irrigation flow meter is a flow meter designed for agricultural irrigation water counting. Agriculture, horticulture, etc. require water for irrigation. And water is becoming more and more expensive. The installation of flow measurement devices allows for effective monitoring and management of agriculture water systems.
The old mechanical water meters and today’s ultrasonic flow meters and electromagnetic flowmeters are widely used.

Read mroe about: Irrigation Flow Meters for Agriculture Water System

Industrial oil flow meters measure the volume or mass of oil. Can realize the mutual conversion of volume and mass.

The main industrial oils are hydraulic oil. Gear Oil. Turbine oil. Compressor oil. Refrigeration oil. Transformer oil. Cylinder oil, heat treatment oil, heat transfer oil, etc. Of course, edible oil can also be produced in the industry. In addition, there are greases with lubricating oil as base oil and thickening agent.

Therefore, whether it is a company that uses, trades, or produces oil, it needs to accurately measure the oil flow.

There are many common oil flow meters, such as turbine flow meters, positive displacement flow meters, gear flow meters, mass flow meters, etc.

Read more about:

Industrial Oil Flow Meters

Hydraulic Oil Flow Meters

Diesel Fuel Flow Meters

Chemical flowmeters are used to measure flow rate that flow through them. You may often hear about ultrasonic flow meters, electromagnetic flow meters, turbine flow meters, volumetric flow or mass flow. Chemical flow meters are common in industries like petrochemical plants and refineries. And play a vital role in the manufacturing process since they help to enhance manufacture efficiency.

Read more about: Chemical Flow Meter Guide

Common sanitary flow meters are sanitary magnetic flow meter and sanitary turbine flow meter. Composed of 304/316 stainless steel. Sanitary flowmeter with Tri-Clamp fittings is easier to install and disassemble. Suitable for food hygiene industry.

Read more about:

Sanitary Flow Meters for Sale

Digital Beer Flow Meters

Marine fuels mainly include light diesel, heavy diesel, fuel oil, and residual fuel oil.

To put it simply, if the tested marine fuel is a low-viscosity, clean fuel. Then you can choose a turbine flowmeter. The price is reasonable and the measurement is stable.

If the marine fuel being tested is heavy oil, high-viscosity fuel. Then it is recommended to choose an oval gear flowmeter.

If the measured marine fuel is a small flow rate. Then it is recommended to use a circular gear flowmeter for measurement.

If the tested marine fuel has impurities. It is recommended to install a filter before the flowmeter.

If you still do not know how to choose the right marine fuel flow meter. You can contact our sales engineer. We will provide you with a suitable marine fuel flow measurement program.

Read more about:

Large-diameter Oval Gear-Marine Fuel Flow Meter

Industrial petrol flow meters|Selection Guide

The hydraulic flow meter is mainly for inline hydraulic system instantaneous flow test and high-pressure test. Industrial Hydraulic oil flow meter, also called hydraulic flow gauge.

Sino-Inst offers Turbine, Mass flow, Oval gear, V-cone, Target, and Orifice flow meters for inline hydraulic oil flow. Features like: bidirectional, high pressure, analog, can be customized as customer need

Read more about:

Hydraulic Oil Flow Meters

Commonly used Cryogenic Flow Meters include cryogenic turbine flow meters, orifice flow meters, mass flow meters, target flow meters, etc. Representative cryogenic fluids include LNG (liquefied natural gas), LN2 (liquid nitrogen), LO2 (liquid oxygen), liquefied ethylene, liquid hydrogen, liquid chlorine and these cryogenic gases. LPG (liquefied petroleum gas) is not included in the cryogenic Fluid.

Read more about:

Cryogenic Flow Meters for Sale

Refrigerant Flow Meter

Read more about: Beginner’s Guide: Variable area flow meter

Application of flow meter in industry

Selecting the right industrial flow meter for your application can be a challenging task. To make it easy, Sino-Inst recommends the best flow meter you should use for your particular gas, liquid, or steam flow application. First, choose your application:

  • Natural gas
  • Compressed air measurement
  • Gas mixing and blending applications
  • Burner control
  • Liquid measurement
  • Steam flow measurement

Based on your application specifications, such as flow rate, pipe size and gas measured, we help you select the perfect flow meter solution for your industry,to improve quality and save money on energy costs, installation, and maintenance.

Extended reading: Ultrasonic Insertion Flow Meter for Lined/Large Pipes

Sino-Instrument is a leading supplier of industrial flow meters, with experience in the design and application of various flow technologies.

To request a quote for industrial flow meters for your application, contact us for more information.

Request a Quote

Please enable JavaScript in your browser to submit the form

Ultrasonic flow measurement


Ultrasonic Flow Measurement, Industrial Inline Flow Measurement.

Ultrasonic flow meters, using the ultrasonic principle, measure the velocity of flow.

We can use a different type of ultrasonic flow meters, like: Portable ultrasonic flow meter, Handheld ultrasonic flow meter, Clamp-on Ultrasonic Gas Flow Meter.

For airflow, natural gas, water, velocity measurement. There are two types of ultrasonic flow meter technologies: Doppler shift and transit-time. Transit-time measures the time differential between signals sent upstream and downstream.

The differential is directly proportional to the velocity of the water.

Transit-time meters are best used for measuring the flow of clean liquids and, as a result, are the most popular type of ultrasonic meter. 

Doppler shift measures the difference in frequency of the sound wave, reflected off gas bubbles or particles in the flow stream, and is suitable for aerated or dirty liquids.

Products for Ultrasonic Flow Meters solutions

Specifications of Ultrasonic Flowmeters

Item

Principle and parameters

Converter

Principle

Transit-time,4 byte floating-point operation in accordance with IEEE754

Accuracy

Inline type:flow meter:±0.5%; heat meter:±1.0%

Clamp on type:flow meter:±1.0%; heat meter:±2.0%

Insertion type:flow meter:±1.0%; heat meter:±2.0%

 

Operation

4-key manipulation with magnetic bar touch or figer touch;

simulation keyboard software

Output

One way 4-20mA analog output

One way OCT pulse signal output

One way Relay output

Input

3 way 4-20mA analog input,accuracy:0.1%;

Acquisition signal of temperature,press and liquid level

Achieve heat measurement by connecting 3-wired PT100

Temperature sensor

Data interface

RS485 serial interface,upgraded by computer,support MODBUS communication protocol

Special cable

Twisted-pair shielded cable and cable length should be no more than 50 m.Transmission distance can achieve 1 km if select the RS 485 interface

pipeline

Pipe material

Steel,stainless,copper,cement,PVC,aluminum,glass steel, cast iron

Pipe diameter

DN15mm-DN6000mm

Straight pipeline

Transducers installation points should be:10 diameters’ straight pipeline from upstream transducer ,5 diameters’ 

straight pipeline from the downstream transducer ;30 diameters’ straight pipeline from the pump

Measuring

Medium

 

Liquid type

Single liquid that can conduct sound wave,such as water,

Seawater, sewage,plant effluent,chemicals,alcohol,beer,oil

etc.

Fluid temperature

-30℃-160

Turbidity

10000ppm,with little bubble

Fluid velocity

0m/s-7m/s

Working

Environment

Temperature

Converter:-20℃-60℃;transducer:-30-160

Humidity

Both of the converter and transducers can work under water,depth underwater ≤2m(After completely sealing)

Power supply

DC8-36V;AC85-264V(optional)

Power consumption

1.5W

ultrasonic flow meter pDF

The Working Principle of Ultrasonic Flow Measurement

Video source: https://www.youtube.com/embed/Bx2RnrfLkQg?start=16

Ultrasonic flowmeters use sound waves to determine the velocity of a fluid flowing in a pipe.

At no flow conditions, the frequencies of an ultrasonic wave transmitted into a pipe, and its reflections from the fluid are the same.

Under flowing conditions, the frequency of the reflected wave is different, due to the Doppler effect.

When the fluid moves faster, the frequency shift increases linearly.

The transmitter processes signals from the transmitted wave, and its reflections to determine the flow rate.

You may like: Digital Flow Meters Guide| Liquid and Gas

Ultrasonic flow meter advantages and disadvantages

Generally, an ultrasonic flow meter is the device, that uses ultrasound to measure the velocity of liquid flow, that helps in determining the volume of liquid flow also.

The ultrasonic flow meters are made using the ultrasonic transducers, which are clamped to the external surface of a pipe, to generate the ultrasonic pulses through the pipe.

When the liquid flows inside the pipe, it creates the time difference in the pulses, and these are examined to calculate the accurate flow velocity of the liquid.

There are many advantages of using the ULTRASONIC flow meters which include:

  • The electronics in the ultrasonic flow meter includes ultrasonic flowmeter detector which compensates and adapts to the changes in the profile of the flow, type of the liquid and material of the pipe.
  • A portable ultrasonic flow meter converter can be used as a direct method to determine the flow rates effectively when compared to the other flow systems.
  • Ultrasonic flow meter converter is inexpensive to use and maintain when compared to the other mechanical flow meters as they are no moving parts in these flow meters.
  • Their design is highly sophisticated and they do not obstruct the liquid flow, so they can be used for sanitary, corrosive and abrasive liquids.

These are the advantages of the ultrasonic flow meters and there are many disadvantages of the Ultrasonic flow meter which include:

  • The main disadvantage of the ultrasonic flow meter is the cost. The cost of the flow meter is very high when compared to the other types of mechanical flow meters.
  • The ultrasonic flow meters are sophisticated when compared to the mechanical flow meters, so it needs experts to repair and maintain the flow meters.

These are the advantages and disadvantages of the ultrasonic flow meters.

Ultrasonic flow meter Types

  1. According to the measurement principle

(1) Time difference method ultrasonic flowmeter;
(2) Frequency difference method ultrasonic flowmeter;
(3) Phase difference method ultrasonic flowmeter;
(4) Doppler ultrasonic flowmeter;
(5) Ultrasonic flowmeters for partially full pipes and river channels that combine liquid level measurement and average velocity measurement.

  1. According to usage

(1) Portable ultrasonic flowmeter;
(2) Fixed (standard pipe section) ultrasonic flowmeter.

  1. According to the installation method of the transducer

(1) Standard pipe section ultrasonic flowmeter;
(2) Clip-on ultrasonic flowmeter;
(3) On-site plug-in ultrasonic flowmeter with hole opening.

  1. According to whether the transducer is in contact with the fluid

(1) Immersion (contact) ultrasonic flowmeter;
(2) Non-invasive (non-contact) ultrasonic flowmeter.

  1. According to the nature of the measured fluid

(1) Liquid ultrasonic flowmeter;
(2) Gas ultrasonic flowmeter.

  1. According to the number of transducer channels

(1) Mono ultrasonic flowmeter;
(2) Two-channel ultrasonic flowmeter;
(3) Multi-channel ultrasonic flowmeter.

Extended Reading: Inline Ultrasonic Flow Meter

Ultrasonic Clamp on Flow Meter is composed of an integrated host and external clamp on sensors. Clamp on Flow Sensors are available at room temperature and high temperature.

Clamp on flow meter (Model: 2000) is composed of an integrated host and ultrasonic clamp on sensor. Clamp on flow meter is widely used in online flow measurement of various liquids. Just stick the external clamp sensor on the pipe surface. Compared with the traditional flowmeter, it does not need to cut off the pipe and flow. The installation is convenient and quick, and the non-destructive installation is truly realized.

Extended reading: Ultrasonic flow detectors types

Portable Ultrasonic Flow Meter is a handheld ultrasonic flow meter. The clamp-on sensor is used to measure liquid flow in industrial pipelines.

Handheld ultrasonic flow meter realizes the non-contact measurement of liquid flow. Also often referred to as Portable Clamp-On Ultrasonic Flow Meter for Liquids.

Handheld Ultrasonic Flow Meter ( Model:2000H) has been successfully applied to measurement work in various industries. The measuring range is 20-6000mm (0.5-20 inches). A non-contact measurement method is adopted. Flexible operation and easy to carry. Conductive or non-conductive, corrosive or non-corrosive liquids can be measured. Various fluids: water, pure water, sewage, sea water, chemical fluids, river water, fuel Oil etc. can be measured.

Extended reading: Portable ultrasonic flow meter for water

Ultrasonic flow meter price

Sino-Inst offers Ultrasonic flow meters with the best quality and best price.

The reference price is between USD 150-700.

The price of ultrasonic flow meter is affected by:

  • Types of sensors
  • Materials
  • Cable length

All of our Flow Meters can work with the NEW AMS TREX !

Ultrasonic flow meter manufacturer

Sino-Inst offers 20 Ultrasonic flow meter products, with Best Price.

Sino-Inst is the manufacturer and supplier of ultrasonic flow meters.

About 13% of these are Petroleum& Chemical flow meters, 4% are water treatment flow indicators. The best Reference price is USD 2000-7000.

A wide variety of ultrasonic flow meter options are available to you, such as free samples, paid samples.

Sino-Inst is clamp-on ultrasonic flow meter suppliers, located in China.

Clamp-on ultrasonic flow meter products are most popular in North America, Mid East, and Eastern Europe.

The United States, and India, which export 99%, 1%, and 1% of ultrasonic level transmitter respectively.

You can ensure product safety by selecting from a certified supplier,

with ISO9001, ISO14001 certification.

In addition to measuring flow rate, ultrasonic technology can also be used to measure liquid level.
The ultrasonic liquid level sensor is also an excellent product for measuring the liquid level of the tank.

Procurement Guide: Ultrasonic liquid level sensors

CO2 Cylinder | Portable Liquid Level Gauge

Frequently
Asked
Questions

Fuel flow meters, also known as turbine flow meters, are the main types of speed flow meters. A freely rotatable impeller is installed in the fluid flowing pipe. When the fluid passes, its motion can make the impeller rotate. The larger the fluid flow rate, the larger the kinetic energy and the higher the impeller speed.

The fluid flow can be determined by measuring the number of revolutions or the number of revolutions of the impeller.

Ultrasonic flow detector is also an ultrasonic sensor. Or called an ultrasonic flowmeter.
Ultrasonic flow detector is composed of sensor and host. The host has wall-mounted, handheld, portable, etc. Sensors are classified into the following models according to the measuring pipe diameter and measuring temperature. It can help users measure pipeline flow under various working conditions.

Optional Transducer

Ultrasonic flowmeter refers to a flowmeter developed based on the principle that the propagation velocity of ultrasonic waves in a flowing medium is equal to the vector sum of the average velocity of the measured medium and the velocity of sound waves in a stationary medium.

It is mainly composed of transducer and converter, and there are different types such as Doppler method, velocity difference method, beam shifting method, noise method and correlation method.

Clamp-on or tube-segment ultrasonic flow meter is based on the principle of “velocity difference method”. It is an instrument for measuring the liquid flow in a circular tube.

Ultrasonic flow meters for measuring liquid flow. Measurement linearity is better than 0.5%. Repeatability accuracy is better than 0.2%. The time difference measurement resolution of up to 40 picoseconds enables the measurement accuracy to reach ±1%.

When choosing an ultrasonic flowmeter, the following points are mainly considered:

1.Measuring medium. 2. Pipe material. 3. Velocity range. 4. Diameter range. 5. Applicable temperature. 6. Medium turbidity. 7. Pipe lining. 8. Acceptable form of installation.

Related Blogs

LPG flow meters

LPG flow meter is used for flow measurement of liquefied petroleum gas. The flow measurement of LPG…

Chemical Flow Meter Guide

What is Chemical Flow Meter? Chemical Flow Meter is also known as chemical resistant flow meter. It…

Cryogenic Flow Meters for Sale

Cryogenic Flow Meters for Highly Accurate and Reliable Cryogenic Fluids Flow Measurement. Sino-Inst offers a variety of…

Hydraulic Oil Flow Meters

Sino-Inst offers a variety of hydraulic oil flow Meters for flow measurement. If you have any questions,…

Sino-Inst, Manufacturer for Ultrasonic Flow Meters. It can measure a single sound-conducting liquid medium of DN 25—150mm. It can measure even liquids such as water, sea water, oil, and slurry.

Sino-Inst’s Ultrasonic Flow Meter, made in China, Having good Quality, With better price. Our flow measurement instruments are widely used in China, India, Pakistan, US, and other countries.

Clamp-on Ultrasonic Gas Flow Meter

Clamp-on Ultrasonic gas flow meters, also called ultrasonic natural gas flow meters, measure liquids, and gas in industrial flow measurement applications.

Ultrasonic gas flow meters are one of the most reliable solutions,

for challenging gas flow measurement applications. (Kind like the portable ultrasonic)

Because the sensor is clamped on to the outside of the pipe,

it is immune to the process compatibility,

concerns of an in-line flow metering technology (What is a flow meter? ).

​​It is now possible to measure natural gassteamcompressed airhydrogen

compressed air and many more using clamp-on flow meters.

Our transducer technology is also ideal for shale gas,

and coal seam gas wellhead applications.

SI-3128 wall mounted ultrasonic flow meter could be applied to a variety of liquid applications,

including ultra-pure liquids, water, chemicals, raw sewage,

reclaimed water, cooling water, river water, plant effluent, alcohol, beer, etc.

What are the types of flow meter?

Features of Clamp-on Ultrasonic Gas Flow Meter

Ultrasonic Flow Meter SI-3128
  • Accuracy: 1%
  • Ingress protection level: IP67 (transmitter), IP68 (sensor)
  • Wide measurement range, pipe size from DN15mm to DN6000mm.
  • Three installation types: wall mounting, DIN-rail mounting, explosion-proof box mounting
  • Could operate with temperature sensors for heat/energy measurement.
  • Could be installed without shut down equipment operation

Specifications for Clamp-on Ultrasonic Gas Flow Meter

Items

Performance Parameter

 

 

      Host

 

Principle

Transit- time ultrasonic flowmeter

Accuracy

±1%

Display

2X20 character LCD with backlight, support the language of Chinese, English and Italy

Signal

Output

1 way 4~20mA output, electric resistance 0~ 1K, accuracy 0. 1%(optional)

1 way OCT pulse output(Pulse width 6~1000ms, default is 200ms)

1 way Relay output

 

Signal

Input

3 way 4~20mA input, accuracy 0. 1%, acquisition signal such as temperature, press and liquid level

Connect the temperature transducer Pt100, can finish the heat/energy measurement

Data

Interface

Insulate Rs485 serial interface, upgrade the flowmeter software by computer, support the MODBUS

Special Cable

Twisted-pair cable, generally, the length under 50 meters ; Select the RS485, transmission distance can over 1000m

Pipe

Installation

Condition

Pipe

Material

Steel, Stainless steel, Cast iron, Copper, Cement pipe, PVC, Aluminum, Glass steel product, liner is allowed

Pipe

Diameter

DN32~6000mm

Straight

Pipe

Transducer installation should be satisfied: upstream10D, downstream 5D, 30D from the pump

Measuring

Medium

Medium

water,sea water ,alcohol,Acid and alkali,waste water,beer,all kinds of oil Single liquid can transmit sound wave.

Temperature

-30~160℃

Turbidity

No more than 10000ppm and less bubble

Flowrate

0~±7m/s,Forward and backward measurement

Work environment

Protection grade

Host:IP67;flow sensor:IP68

temperature

Host:-20~60℃;flow sensor:-30~ 160℃

Humidity

Host: 85%RH; Flow sensor:can measure under water, water depth^2m (tansducer sealed glue)

Power Supply

DC8~36V or AC85~264V

Power

Consumption

1.5W

Dimension

132*150*85mm(host)

You may like: Vortex shedding flow meter

Gases that can be measured with ultrasonic clamp-on flowmeters include:

Compressed AirHydrogenOxygen
NitrogenSteamNatural Gas
PropaneButaneCorrosive Gases
Erosive GasesHigh Purity GasesSterile Gases
Toxic GasesInert GasesCompressed Air

What is ultrasonic gas meter?

Ultrasonic flowmeters use sound waves to determine the velocity of a fluid flowing in a pipe.

At no flow conditions,

the frequencies of an ultrasonic wave transmitted into a pipe,

and its reflections from the fluid are the same.

Under flowing conditions, the frequency of the reflected wave is different due to the Doppler effect.

When the fluid moves faster, the frequency shift increases linearly.

The transmitter processes signals from the transmitted wave,

and its reflections to determine the flow rate.

Transit time ultrasonic flowmeters send and receive ultrasonic waves,

between transducers in both the upstream and downstream directions in the pipe.

At no flow conditions,

it takes the same time to travel upstream and downstream between the transducers.

Under flowing conditions, the upstream wave will travel slower and take more time than the (faster) downstream wave.

When the fluid moves faster, the difference between the upstream and downstream times increases.

The transmitter processes upstream and downstream times to determine the flow rate.

They represent about 12% of all flowmeters sold.

The ultrasonic principle can also be used to measure water depth. Please refer to Portable Ultrasonic Water Depth Gauge for water depth measurement.

You may like: Nitrogen flow meter

How does a clamp-on flow meter work?

A clamp-on ultrasonic gas flow meter produces signals,

that is five to ten times more powerful,

then those of traditional ultrasonic transducers.

The new clamp-on transducers produce clean, coded signals with very minimal background noise.

The result is that a clamp-on gas flow meter can now provide optimum performance,

even with low-density gas applications.

Today, our ultrasonic clamp-on gas flowmeters such as the SI-3128 can measure the flow of any gas,

and then calculate mass flow using a pressure transmitter connected to the analog input.

Inline ultrasonic flowmeters

The SI-3000H Portable Ultrasonic Flowmeter is a widely used time difference ultrasonic flowmeter,

for on-line calibration and inspection of liquid flow in various industrial sites.

Handheld ultrasonic flow meter, also known as Portable Doppler flow meter, or Inline ultrasonic flow meter.

SI-2000H handheld ultrasonic flow meter is a representative of portable ultrasonic flow meters.

More Gas Flow Meters

Sino-Instrument offers 20 Gas flow meter products, with Best Price.

About 13% of these are Petroleum& Chemical flow meters, 4% are water treatment flow indicators.

The best Reference price is USD 2000-7000.

A wide variety of gas flow meter options are available to you, such as free samples, paid samples.

Sino-Instrument is clamp-on ultrasonic flow meter suppliers, located in China.

clamp-on ultrasonic flow meter products are most popular in North America, Mid East, and Eastern Europe.

The United States, and India, which export 99%, 1%, and 1% of ultrasonic level transmitter respectively.

You can ensure product safety by selecting from a certified supplier,

with ISO9001, ISO14001 certification.

Of course, you can also choose other gas flow measurement instruments, like:

https://www.drurylandetheatre.com/coriolis-mass-flow-meter-si3131/
https://www.drurylandetheatre.com/steam-flow-meter-inline-vortex-flow-meters/
https://www.drurylandetheatre.com/magnetic-flow-meters/
https://www.drurylandetheatre.com/si-rsl-thermal-mass-flowmeters/

Request a Quote